BURNER IGNITION
Lighting with a Match
A) Open the grill lid (1).
m DANGER
Failure to open the lid before igniting the
grill's burners, or not waiting five minutes
to allow the gas to clear if the grill does not
light, may result in an explosive flare-up
which can cause serious bodily injury or
death.
B) Make sure ALL burner control knobs are turned off (2).
Check by pushing burner control knobs in and turning
them clockwise until they stop.
m WARNING: The burner control knobs must
be in the off ( ) position before you turn
on the LP tank valve. If they are not in the
off ( ) position when you turn on the LP
tank valve, the "excess gas flow control"
feature will activate, limiting the flow of
gas from the LP tank. If this should occur,
turn off the LP tank valve and burner
control knobs. Start over.
m DANGER
When the "excess gas flow control" feature
is activated, a small amount of gas is still
flowing to the burners. After turning off the
LP tank valve and burner control knobs,
wait at least five minutes for the gas to clear
before attempting to light the grill. Failure
to do so may result in an explosive flare-up,
which can cause serious bodily injury or
death.
C) Turn the LP tank on by slowly turning the tank valve
counterclockwise; wait 60 seconds (3).
D) Strike a match and put the flame under the matchlight
hole (4). While holding lit match, light the outside
burner by pushing the large burner control knob in and
turning it counterclockwise to start/high ( ) position (5).
E) Check that the burner is lit by looking through the
cooking grates. You should see a flame.
m WARNING: Do not lean over the open
grill while igniting. Keep your face and
body at least 12 in (30 cm) away from the
matchlight hole when lighting the grill.
m WARNING: If the burner fails to ignite
within five seconds, stop, turn the burner
control knob to off and wait five minutes
to allow the gas to clear before you try
again or light with a match.
F) After the outside burner is lit, you can turn on the inside
burner. Push in the small burner control knob and turn
it to start/high ( ) position (6). The inside burner will
then be ignited by the outside burner.

TO EXTINGUISH BURNER

Push each burner control knob in and turn it clockwise to
the off ( ) position. Turn gas supply off at the source.