Burner Ignition & Usage; Methods Of Burner Ignition; Burner Ignition Electronic Ignition System; To Extinguish Burner - Weber 3200 Owner's Manual

Hide thumbs Also See for 3200:
Table of Contents

Advertisement

Available languages

Available languages

METHODS OF BURNER
IGNITION
There are two ways to ignite
the burner. The first is by using
the ignition system built into
your grill. The second is with a
match.
Next are the steps for igniting
your grill using the ignition
system. On the following page
are steps for igniting your grill
with a match.
Summary lighting instructions are posted on
the cart leg under the burner control knobs.
Some batteries have a plastic
protective wrap around them.
This plastic must be removed
before you attempt to ignite
your grill. Do not confuse this
plastic with the battery label.
BURNER IGNITION & USAGE
BURNER IGNITION
Electronic Ignition System
The electronic ignition system ignites the burner with a
spark from the igniter electrode inside the Gas Catcher™
ignition chamber. You generate the energy for the spark by
pushing the igniter button. You will hear the igniter clicking.
A) Open the grill lid (1).
m DANGER
Failure to open the lid before igniting the
grill's burners, or not waiting five minutes
to allow the gas to clear if the grill does not
light, may result in an explosive flare-up
which can cause serious bodily injury or
death.
B) Make sure ALL burner control knobs are turned off (2).
Check by pushing burner control knobs in and turning
them clockwise until they stop.
m WARNING: The burner control knobs must
be in the off ( ) position before you turn
on the LP tank valve. If they are not in the
off ( ) position when you turn on the LP
tank valve, the "excess gas flow control"
feature will activate, limiting the flow of
gas from the LP tank. If this should occur,
turn off the LP tank valve and burner
control knobs. Start over.
m DANGER
When the "excess gas flow control" feature
is activated, a small amount of gas is still
flowing to the burners. After turning off the
LP tank valve and burner control knobs,
wait at least five minutes for the gas to clear
before attempting to light the grill. Failure
to do so may result in an explosive flare-up,
which can cause serious bodily injury or
death.
C) Turn the LP tank on by slowly turning the tank valve
counterclockwise; wait 60 seconds (3).
D) Light the outside burner by pushing the large burner
control knob in and turning it counterclockwise to start/
high ( ) position (4).
E) Push and hold in the igniter button (5). You will hear the
igniter clicking.
F) Check that the burner is lit by looking through the
cooking grates. You should see a flame.
m WARNING: While igniting the grill or
cooking, never lean over open grill.
m WARNING: If the burner fails to ignite
within five seconds, stop, turn the burner
control knob to off and wait five minutes
to allow the gas to clear before you try
again or light with a match.
G) After the outside burner is lit, you can turn on the inside
burner. Push in the small burner control knob and turn
it to start/high ( ) position (6). The inside burner will
then be ignited by the outside burner.

TO EXTINGUISH BURNER

Push each burner control knob in and turn it clockwise to
the off ( ) position. Turn gas supply off at the source.
3
5
6
WWW.WEBER.COM
1
2
4
25

Advertisement

Table of Contents
loading

Table of Contents