Disassembling The Fork Leg/Slider Unit - APRILIA LEONARDO 250 Workshop Manual

Hide thumbs Also See for LEONARDO 250:
Table of Contents

Advertisement

CYCLE PARTS
7.10.4.

DISASSEMBLING THE FORK LEG/SLIDER UNIT

NOTE the following operations refer to a single fork leg/slider
assembly, but apply to both of them.
For the disassembly of the rubber cap (1), snap ring
(2), seal plug (3) complete with "GACO" O-ring (4),
spring (5), carry out the operations described in section
7.10.2 (CHECKING THE OIL LEVEL) on the leg/slider
unit that must be disassembled, excluding the last two
operations (oil level check).
CAUTION
The oil may flow out.
The leg/slider unit is full of oil. Neither overturn
it, nor incline it excessively during the removal.
Remove the leg/slider unit, see 7.7.3 (REMOVING
THE LEG/SLIDER ASSEMBLY ).
Prepare a graduated container with at least 200 cu.m
capacity..
Make the tube get into the slider completely, rotate the
tube/slider unit and drain the oil in the container.
CAUTION
Check the oil quantity.
If it is lower than 148 cu.cm, top up or change.
Unscrew and remove the screw (6) (slider bottom) and
take the copper washer (7).
Withdraw the tube (8) complete with pumping element
(9).