ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS s i s t e m a i r . c o m TECHNICAL MANUAL SENSE retractable tube system V 1.0.1...
Page 3
• Type: central vacuum system domestic sector • Revision 1.0.1 SENSE INDEX CHOICE OF VACUUM UNIT MULTI SENSE AND MONO SENSE SYSTEM TECHNICAL FEATURES WARNINGS FOR INSTALLING THE SENSE SYSTEM 4.1 Installation height 4.2 Installation on plasterboard 4.3 IWall installation...
Page 4
This manual is designed for an installer who has the appropriate training and experience to carry out the installation of a central vacuum system. It is essential that only Sistem Air brand components are used for the installation The installer is responsible for carrying out the work in accordance with local laws.
If, on the other hand, only one outlet is to be installed, it is possible to use the Mono Sense vacuum inlet, a system that is simpler in its use.
Page 6
Instruction manual 4 - WARNINGS FOR INSTALLING THE SENSE COUNTER SOCKET 4.1 - INSTALLATION HEIGHT If the counter socket is oriented downwards, with the inlet to connect to the pipe network downwards, it is recommended not to install the counter socket at a height of less than 40 cm.
Page 7
4.2 - INSTALLATION ON PLASTERBOARD Fasten the counter socket to the wall upright Make sure it is aligned (fi gure 1) and has free space behind the socket. Inquadra per l’installazione Fits for installation Cadres pour l'installation Rahmen für die installation Enfoca para la instalación MURARE A FILO INTONACO FLUSH WALL-MOUNTED...
Instruction manual 4.3 - WALL INSTALLATION Insert the back of the counter socket into the wall (fi gure 4). Once the pipe network has been connected and the Inquadra per l’installazione Fits for installation Cadres pour l'installation Rahmen für die installation electrical connection made, embed the back of the Enfoca para la instalación MURARE A FILO INTONACO...
Page 9
2”/ 51mm and its length should be equal to the length of the retractable tube, plus 10/15cm of excess. Only specifi c fi ttings (fi gure 1) for the Sense system can be used for the pipe network. All this is con- tained in the Sense system installation kit Art.
Page 10
Instruction manual Any lumps or excess glue could damage the hose covering, as it retracts into the pipe network. To avoid this, ensure that the glue is applied to the male part of the fi tting and never to the female part (fi...
Page 11
The use of 90° bends reduces the pick-up speed of the retractable tube and increases its pull-out force from the socket, therefore it is recommended not to use more than 3 90° bends per socket. Avoid using two 90° bends one after the other (fi gure 4).
Page 12
6 - ELECTRICAL CONNECTION 6.1 - STANDARD ELECTRICAL CONNECTION Everything indicated below is also valid for the Mono Sense system, as the fi gures are for illustra- tive purposes only. Connect the cable of the vacuum unit’s micro line in parallel in each socket, to connect the vacuum acti- vation contact.
Page 13
6.2 - ELECTRICAL CONNECTION WITH WIRELESS ON/OFF SYSTEM Everything indicated below is also valid for the Mono Sense system, as the fi gures are for illus- trative purposes only. Mandatory installation of receiver art. 3301.12 (optional) and its handle. Or it is possible to integrate the System Tech Flisy 2 Sense kit art.7039.4W (optional).
Instruction manual 7 - COVER INSTALLATION Everything indicated below is also valid for the Mono Sense system, as the fi gures are for illus- trative purposes only. Once installation of the socket is complete, the cover with closing panel can be applied.
8 - OPERATION To use the Sense socket, proceed according to the instructions in the following chapters. 8.1 - MULTI SENSE SWITCH-ON Pipe Lever Open the panel Turn the lever 180° anticlockwise and pull out the pipe Pipe blocking handle...
Page 16
Instruction manual 8.2 - MULTI SENSE SWITCH-OFF Handle Close the pipe vacuum connection with your hand to collect the pipe inside the pipe network To unlock the tube, push the upper handle Lever Lever Once the pipe is retracted completely within the socket, rotate the lower lever 180°...
Page 17
8.3 - MONO SENSE SWITCH-ON Pipe blocking handle Open the panel and pull out To lock the pipe pull the handle for- the pipe ward Button Pull the bottom right button to start vacuum 28/08/2023 Rev:1.0.1...
Page 18
Instruction manual 8.4 - MONO SENSE SWITCH-OFF Handle Close the pipe vacuum connection with your hand to collect the pipe inside the pipe network Push the upper handle to lock the pipe Button Once the pipe is retracted completely within the socket, press the bottom right button to stop vac- 28/08/2023 Rev:1.0.1...