B. Connecting Camera Control to the K-1200 Internal Relay
Another internal relay in the K-1200 can be used to trigger a camera controller. When the K-1200 makes a call, it will
energize the relay and hold it on until the call is done.
* Note: To prevent unwanted radio interference, route the connecting wires through the included ferrite core.
** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum
insulation of 0.082 inches. Cut off stripped ends prior to terminating.
Rear View
of the K-1200
C. Using the K-1200 with a C-1000B
In some instances it may be a concern that the Door Strike relay is outside the door. In this situation, a second con-
troller such as a C-1000B can be used. Be sure to disable the door strike code for the K-1200 (see Programming sec-
tion H).
Notes: 1. The C-1000B must be in the "Analog Station Mode" (refer to the C-1000B Technical Practice). 2. The K-
1200 keyless entry codes can not be used in this application. 3. The K-1200 will hang-up during doorstrike activation.
120V AC
13.8V AC
Adapter
(included)
* Earth
Ground
CO line or Analog
PABX/KSU Station
4
* Ferrite Core
(included)
K-1200
Model:
P/N:
260878-1
DEV:
S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
Model C-1000B (not included)
VIKING
©
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
COM
N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
SIG GND
SIG GND
SIG GND
VIDEO 1 IN
VIDEO 2 IN
VIDEO OUT
C
LED1
EARTH
C.O. LINE
OUT TO
KEYLESS
DOOR
GND
INPUT
PHONES
C.C. INPUT
BOX 1
Black
Black
Red
Green
Blue (COM)
Violet (NC)
White (NO)
MODEL C-1000B
ON
1
2
3
C
C
TALK
BATTERY
LED2
LED3
OFF
ON
DOORBOX
DOOR
N.O. COM N.C.
N.O. COM N.C.
13VAC PWR
BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
Doorstrike/Magnetic Lock 2
120V AC
Red
Green
1
2
3
4
5
6
7
8
9
0
*
Model
#
K-1200
VIKING
©
120V AC
Camera
Controller
(not included)
or
** Gel-Filled Butt
Connectors (included)
Talk Battery Switch
OFF
ON
DIP Switches
ON
ON
OFF
1
2
3
120V AC
5A@30V DC/
250V AC maximum
CO Line