CIRCUIT DESCRIPTION
3. Test mode (Cassette deck)
3-1. Initial setting
The deck is set initially under the following condi-
tions.
Power
Mechanical mode
Direction
Right to operate
CCRS/CRLS
Operation mode
DOLBY NR
Input
REC level
All mute
Erasing head
R/P
A/B
Reel LED
> ON
: Stop
: Both A and B are set forward.
:B
: OFF
: U mode
: OFF
: Tuner
: Initial value
Playback equalizer :
> ON
: OFF
: Play
[A
> ON
120NSP
3-2. Types of test mode
(1) Test 1
(2) Manual adjustment
(3) Automatic adjustment
3-3. Setting of test mode
The machine is set in the test mode under the follow-
ing port conditions when it is reset.
AUTO ADJ
MANU ADJ
TEST1
INITIAL SET
DON'T CARE
When turning on the power for the Cassette deck in-
dependently, be sure to connect AC16V (No. 7 or 8)
and D17 (ANODE) of (X28){A/6) .
(Remove this connec-
tion after the power is turned on.)