Setting C - Repeat Announcement Option
The 1600A can be programmed to play the announcement from 1-9 times,
or to continuously repeat the announcement every 8 seconds until a
Touch Tone
is detected from the distant party. The I.D. number (if pro-
grammed) will be sent and the call connected LED will turn on automati-
cally after the announcement has stopped repeating.
* Note: The factory default for the 1600A series phone is to repeat until a
H. Recording the Announcement
Step 1. Call into the 1600A series phone with a Touch Tone phone and access programming.
Step 2. Enter
4, wait for the tone and then begin recording. Sixteen seconds of record time is available.
Step 3. Enter any Touch Tone to stop the recording. Playback is automatic.
Step 4. Enter
5 to review the announcement again.
Step 5. If you choose to not use a voice announcement, enter ✱3 to clear the recording.
Example: "Elevator number 1215, located in the Financial Building, needs assistance. Press the asterisk (✱) key on
your telephone to start and stop this announcement..."
I. Automating the Call Connected LED
There are two methods of turning on the Call Connected LED. The LED will turn on after a Touch Tone ✱ is detected
from the distant party or after the voice announcer is finished playing a programmed number of times. If you want the
Call Connected LED to light automatically when the call has been answered, but you don't want a voice announcement
to be played, follow these programming steps:
Step 1:
Access Programming as shown in section A
J. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations
the microphone sensitivity may need to be decreased as shown below. Caution: Setting the microphone gain too high
may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing.
Speaker
Volume
K. Central Station Programming
The standard 1600A emergency phone is capable of communicating using the "Ademco Contact I.D.", "Ademco High
Speed", "DTMF 4+1 Express", or the "DTMF 4+2 Express" formats. All formats use the programming memory location
#20 to store the account code and alarm details.
Step 2:
Make a short (1 second) recording of silence
DIP
Switch
1
Microphone
1
Sensitivity
2
2
DIP Switches
3
1
2
3
3
Off
On
(DIP Switches shown
in factory setting)
Touch Tone
0
1-9
is detected (digit 0).
Position
Description
ON
"HELP" / "CALL" button alternately connects
and disconnects calls (factory default)
OFF
"HELP" / "CALL" button connects calls only
ON
Incoming calls answered (factory setting)
OFF
Incoming calls are not answered
ON
Normal operation mode (factory setting)
OFF
Learn mode - Any incoming calls are auto-
matically entered into the programming
mode (no security code required). Use this
option if you have forgotten your security
code.
Setting C
Repeat every 8 secs*
Repeat 1-9 times
Step 3:
Enter digits: 001000#17