3. Connect the Control Box
Spout
Wires
IMPORTANT! The control box and cover have slots for the sensor cables. Use care
not to pinch the sensor cables when installing the cover.
Connect the 2-pin power connector (white) from the DC-DC booster assembly to
the 2-pin power connector (white) of the control box.
Connect the 3-pin sensor cable from the valve cover to the 3-pin sensor cable from
the spout (red, white, and green cables).
Connect the 2-pin sensor cable from the valve cover to the 2-pin sensor cable from
the spout (orange and black cables).
Guide the sensor cables through the slots in the control box.
Loosely secure the cover to the control box for future access.
1561532-2-A
2-Pin
Sensor
Cable
Connector
3-Pin
Sensor
Cable
Valve
Box
DC-DC Booster Assembly
Slots
2-Pin Power
Connector
to control box
Solenoid
Cable
2-Pin
Power
Connector
2-Pin
Solenoid
8
2-Pin
3-Pin
Sensor
Sensor
cable
cable
2-Pin Power Molex
Connector to
Battery/AC/Hybrid