Download Print this page

KitchenAid K5-A Service Instructions Manual page 30

Food preparer
Hide thumbs Also See for K5-A:

Advertisement

Trouble
Possible Cause
Remedy
BAD
SPARKING AT CON-
Open-circuited
condenser.
Disconnect one
yellow
condenser
lead
and
TACT
POINTS OR
turn
switch
knob to the No. I
position.
If
BURNED CONTACTS
a very faint
spark ca
n
be
seen
when the
lead is
touched to the other three leads
when the
connection
is made
or
broken,
the
condenser is
not
open.
If the
con-
denser is in
good
condition,
a
noticeable
decrease in
sparking is
apparent
at
the
contact
points.
Replace a fa
ulty
co
n-
denser.
Faulty
resistor.
Turn
the switch
knob to high
speed and
break the
circuit
through the contacts
by
lifting
the
inverted
"T" shaped part
of
the
spring on
which the
contacts are
mounted. If the mixer
comes
to
a
full
stop,
the
resistor
is
faulty
and
should
be
replaced.
BAD SPARKING AT
Worn
motor
brushes.
Remove brushes
and check
that they
are
MOTOR
BRUSHES
not
worn
to
less
than
5/
16 inch.
Replace
with new
brushes
if
excessively
worn.
(Grade
F-6)
Rough
commutator.
Remove the
trim
strip and
hold
a
narrow
piece of fine sandpaper
against
the
com-
mutator
as
the
motor
is running.
If
th
e
commutator
cannot
be smoothed down in
this
manner,
remove the
armature and
turn it down in
a lathe.
Faulty
armature
or shorted motor field
.
Disassemble
and
check motor.
29

Advertisement

loading

This manual is also suitable for:

K-45