IMPORTANT SAFETY INSTRUCTIONS ESD Warning To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before touching any internal materials. When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be followed to make sure people, products, and tools are as free of static charges as possible.
Page 3
IMPORTANT SAFETY INSTRUCTIONS READ these instructions. KEEP these instructions. HEED all warnings. FOLLOW all instructions. DO NOT use this apparatus near water. CLEAN ONLY with dry cloth. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Page 4
WARNING: To reduce the risk of fire or electrical shock, do not expose this apparatus to rain or moisture. WARNING: No naked flame sources – such as lighted candles – should be placed on the product. CAUTION: To be installed by instructed, or skilled, persons only. WARNING: This product is intended to be operated ONLY from the voltages listed on the back panel or the recommended, or included power supply of the product.
Page 5
FCC SDOC SUPPLIER’S DECLARATION OF CONFORMITY: HARMAN Professional, Inc. hereby declares that this equipment is in compliance with the FCC part 15 Subpart B. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 6
ENVIRONMENTAL: 该设备的设计和测试是在海拔 2000 米高度以下进行的, 它只适用在海拔2000 米以下的地区. 在海拔2000 米以 上使用可能会导致潜在的安全隐患. This device is designed and evaluated under the condition of altitude below 2000 meters above sea level; it can only be used in locations below 2000 meters above sea level. Using the device above 2000 meters could result in a potential safety hazard.
Page 7
EU COMPLIANCE INFORMATION: Hereby, Harman Professional, Inc. declares that the equipment type MU-1000/1300/2300/3300 is in compliance with the following: European Union Low Voltage Directive 2014/35/EU; European Union EMC Directive 2014/30/EU; European Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU and as amended by 2015/863;...
Table of Contents Contents IMPORTANT SAFETY INSTRUCTIONS ............................... 2 TABLE OF CONTENTS ..................................8 WHAT’S NEW? ....................................10 ..........................10 UPPORTS MULTIPLE ARMAN PROTOCOLS NATIVELY ..................................... 10 ONTROL ............................10 TANDARD ANGUAGE CRIPTING UPPORT ..........................10 ODULE AND RIVER ESIGN ODULE SUPPORT USB H ......................................
Page 9
IR/SERIAL P ..................................... 24 ICSLAN P ....................................25 ORTS ICSLAN N ................................25 SING THE ETWORK ICSLan Network Settings ................................25 DHCP Server .................................... 25 Opening LAN and ICSLAN Sockets from Code ..........................25 LAN 10/100 P ..................................25 IPv4 ......................................25 IPv6 ......................................
Harman gear. AMX touch panels, Crown DCi Amplifiers, BSS Contrio keypads and Soundweb London devices are all available to the controller from these communication buses. Future Harman gear that is HControl aware will all work with the MU-series controllers.
Features MU-Series Controller Features Name (SKU) Features MU-1000 (AMX-CCC000) PoE Powered (802.3af – standard power) 1 LAN Ethernet port 1 ICSLan Control Network port Small form factor – 1” x 5” x 5” DIN Rail mountable with DIN Rail Clip (AMX-CAC0001) 4 GB DDR3 RAM 8 GB eMMC Storage 2x USB 2.0 Type A Host port...
MU-1000 The MU-1000 (AMX-CCC000) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is PoE powered and has a small form factor for easy installation. It features the MUSE scripting engine which supports a variety of standard programming languages to create the business logic for the control system.
Page 13
…MU-1000 specifications continued ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network USB Host Port 2x Type-A USB host port • USB Mass Storage – for external logging • FLIRC – IR Receiver for IR hand control input General Specifications: Operating Environment Operating Temperature: 32°...
MU-1300 The MU-1300 (AMX-CCC013) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is a small form factor for easy installation. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system. A complete list of device specifications is listed below.
Page 15
…MU-1300 specifications continued P1 / P2 LED Programmable LEDs available to control scripts Serial TX / RX LED Activity LEDs for each port in each direction. Blinks on activity. IR TX LED Activity LEDs for the IR/Serial port. Blinks on transmission. I/O LED LED indication of I/O Status.
MU-2300 The MU-2300 (AMX-CCC023) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is built for installing in an equipment rack. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system. A complete list of device specifications is listed below.
Page 17
…MU-2300 Specifications continued Rear Panel Components Power 3.5mm Phoenix 2-pin connector with retention screws for 12vdc input LAN Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP Client ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network RS-232/422/485 Port 1 3.5mm Phoenix 10-pin connector...
MU-3300 The MU-3300 (AMX-CCC033) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is built for installation in an equipment rack. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system.
Page 19
…MU-3300 Specifications continued Rear Panel Components Power 3.5mm Phoenix 2-pin connector with retention screws for 12vdc input LAN Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP Client ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network RS-232/422/485 Port 1 &...
Mounting the controller Mounting the MU-2300 and MU-3300 Use the rack-mounting brackets (supplied with the MU-2300/3300) for equipment rack installations. Remove the mounting brackets and apply the rubber feet to the bottom of the controller for flat surface installations. Installing the Controller into an Equipment Rack The MU-2300/3300 each ship with removable rack ears for installation into an equipment rack.
Front Panel Components The following sections list the front panel components on the MU-series controllers. Each component is featured on all MU-series controllers except where noted. Program Port The front panel of all models features one USB-C port for connecting the controller to a PC via USB cable. The Program port uses a standard Type-C-to-Type-A or Type-C-to-Type-C USB cable that supports USB 2.0/1.1 signals to connect to a PC.
ICSLAN LEDs The ICSLAN LEDs light green when there is an active link on the corresponding ICSLAN port. The light toggles off when a data packet is sent or received. The MU-1000, MU-2300 and MU-3300 each have one ICSLAN LED SERIAL LEDs The SERIAL LEDs are two sets of LEDs which light to indicate that the RS-232 ports are transmitting or receiving RS-232, 422, or 485 data (red = TX, yellow = RX).
Wiring and Connections Overview This chapter provides details, specifications, wiring diagrams, and other important information for all port and connectors available on the MU-series controllers. Serial Ports The MU-series controllers each feature device control serial ports that support either RS-232 or RS-232, RS-422, and RS- 485 communication protocols.
Relay Ports Relay Pinout Signal Function Signal Function Relay 1 Common Relay 1 NO Relay 2 Common Relay 2 NO Relay 3 Common Relay 3 NO Relay 4 Common Relay 4 NO Relay 5 Common Relay 5 NO Relay 6 Common Relay 6 NO Relay 7 Common Relay 7 NO...
AMX Ethernet Equipment in a way that is isolated from the primary LAN connection. The ICSLAN port is a 10/100 Port RJ-45 connector and Auto MDI/MDI-X enabled. The controller will listen on either port for Harman communication buses such as ICSP, HIQnet, and HControl.
INPUT PWR Connector The MU-1300, MU-2300 and MU-3300 controllers feature a 2-pin 3.5 mm Phoenix connector with screw retention for providing DC power to the controller. The suggested power supply for the MU-series controllers is a 13.5 VDC 6.6 A output, suitable for 50°...
Time zone returns to default • User accounts are deleted • • The default credentials of "admin" with default "password" are restored • "support" user is disabled Any configured syslog server is disabled and cleared • Any configured flash media logging is disabled •...
Need help?
Do you have a question about the AMX MU Series and is the answer not in the manual?
Questions and answers