9.3.10 To connect the safety thermostat (normally closed contact)

EPRA14~18D + ETBH/X16E
Daikin Altherma 3 H HT W
4P644736-1D – 2023.10
1 Front panel
2 Switch box cover
3 Switch box
2 Connect the power consumption digital inputs cable to the appropriate
terminals as shown in the illustration below.
A
B
C
B
a Installation of EKRP1AHTA is required.
3 Fix the cable with cable ties to the cable tie mountings.
Wires: 2×0.75 mm²
Maximum length: 50 m
Safety thermostat contact: 16 V DC detection (voltage supplied by PCB).
The voltage-free contact shall ensure the minimum applicable load of
15 V DC, 10 mA.