The sensors must be connected to the JOB SELECTOR inputs shown in paragraph 3.1.2. The weight
of each input depends on the number of selectable jobs indicated in the configuration.
From 1 a16 jobs with or without use of the ENABLE input:
JOB SELECTOR IN7
JOB SELECTOR IN6
JOB SELECTOR IN5
JOB SELECTOR IN4
From 17 to 32 jobs without use of the ENABLE input:
JOB SELECTOR IN7
JOB SELECTOR IN6
JOB SELECTOR IN5
JOB SELECTOR IN4
JOB SELECTOR IN3
From 17 to 32 jobs using the ENABLE input:
JOB SELECTOR IN5
JOB SELECTOR IN6
JOB SELECTOR IN7
JOB SELECTOR IN8
JOB SELECTOR IN9
JOB SELECTOR IN3
With more than 32 jobs with or without use of the ENABLE input:
JOB SELECTOR IN4
JOB SELECTOR IN5
JOB SELECTOR IN6
JOB SELECTOR IN7
JOB SELECTOR IN8
JOB SELECTOR IN9
JOB SELECTOR IN3
3.8 Special waste selection
To select which reject causes activate the REJECTED2 output , use the Visual Point Setup software.
In the tools menu Settings select the item Special rejected bit mask . A window will appear where
you can enter the number obtained from the sum of the values of each reject cause that is of interest
to recognise.
Weight
1
2
4
8
Weight
1
2
4
8
16
Weight
1
2
4
8
16
ENABLE
Weight
1
2
4
8
16
32
ENABLE
16