Input operation description:
Function
START
CCT
RESET
ENABLE
EMERGENCY OK
JOB SELECTOR
RED BASKETBALL
GREEN
BASKETBALL
3.1.5 Output terminal block (X4)
Outputs for 24VDC users. For inductive loads, such as valves and relays, a diode must be mounted
in parallel with the coils to eliminate overvoltage.
First
Function
name
GOOD
OUT0
REJECTED
OUT1
GO
OUT2
PROTECTION
OUT3
BUZZERS
CONTACT/BOOSTER
OUT4
SETPOINT
PULL UP
TANK
OUT5
RETURN
REJECTED2
MARKGOOD
OPENDOOR
OUT6
OUT7
NU
Power ground
0VP
Description
Request to start a new cycle
"Top dead center" signal, used as a reset for a new cycle and in AND with the zero mark of the
encoder for zeroing the transducer
Optional. Re-enables the tool after a discard.
Optional. Cycle start enabling signal.
Optional. Guards ready signal.
Optional. Job selection command.
Optional. Waste piece trashed signal.
Optional. Good piece trashed signal.
clamp
Description
X4.1
X4.2
X4.3
X4.4
Function selected by instrument configuration
X4.5
Feature selected based on press type or tool configuration
PK series cylinder tank management
X4.6
Return cylinder management
Special reject signal
Good piece stamping signal
X4.7
X4.8
X4.9
Do not connect
X4.10
This terminal is connected directly to terminal X3.11. Allows for cleaner
wiring when connecting utilities directly to this terminal block
10
Need help?