Summary of Contents for Lode Brachumera Sport

  • Page 1 - Manual Brachumera Sport Sports Medicine Lode BV Zernikepark 16 NL 9747 AN Groningen The Netherlands t: +31 50 571 28 11 f: +31 50 571 67 46 @: ask@lode.nl www.lode.nl M965911/21 / VERSION: 1.0 - 2019-09-30...
  • Page 2: Table Of Contents

    7 - Controlling the Ergometer 7.1 - Manual Control Ergometer 7.2 - External Control with ECG or Ergospirometry System 7.3 - External control with Lode Ergometry Manager 8 - Exchange Parts of the Brachumera 8 - Exchange Parts of the Brachumera 8.1 - Exchange Handgrips/Pedals...
  • Page 3: Intended Use

    The maintenance and service of the medical device has to be done by a well-trained service engineer who is working for a Lode distributor and is specifically trained regarding the MD by the International Service Coordinator of Lode.
  • Page 4 The operator should not touch accessible parts and the patient simultaneously. Read this manual before using the device and follow it carefully. The operator should instruct the test subject prior to performing an exercise protocol. If, at any time during exercise, the test subject feels faint, dizzy, or experiences pain, stop the test and he or she should be consulted by the physician.
  • Page 5 Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. Be aware that during extreme exercise testing the head of the participant can hit the housing of the Brachumera.
  • Page 6 In case of heavy loads, always check if the Brachumera is properly fixated. The installation should only be done by authorized persons who follow the installation instructions. Do not spill any liquid over the device. Only use the device at normal operating temperature and air pressure (see specification).
  • Page 7: Contra Indication

    Your device may be executed with heart rate measurement, blood pressure measurement, and / or SpO2 (blood saturation) measurement. These measurements may be inaccurate, depending on use circumstances. These measurements are indicative and cannot be used for diagnostic purposes. When replacing cranks, pedals or handle bar be sure to mount the parts in the correct position and tighten the connection firmly.
  • Page 8: Validity

    4 - Validity This manual covers all Brachumera versions starting with the following serial number: 965911 Brachumera Sport: S/N 20220001 - 965921 Brachumera Sport PFM: S/N 20220001 - Date of first issue: 2022-11-18 4.1 - Description of Parts 1. Handgrips for transport (APPLIED PART) 2.
  • Page 9 4. Type plate 5. Symbol plate 6. Communication Interface Module 7. Network Module 8. Service port (not to use) 9. Power inlet and On/Off switch 10. Potential Equalization Conductor M965911/21 / VERSION: 1.0 - 2019-09-30 9/26...
  • Page 10: Installation

    5 - Installation 5.1 - Install the device - Unpack the device while leaving the transport straps in place. - Place the device in the location where it will be used. - Remove transport straps and remaining packaging materials. - Connect the power cord to the line output at the required voltage (see type plate). - Remove all objects from the device.
  • Page 11 Free area when used with stand. M965911/21 / VERSION: 1.0 - 2019-09-30 11/26...
  • Page 12: Connecting Cables

    5.3 - Connecting Cables The connection for the power cord and optional connectors for external devices are placed at the backside of the ergometer, so they are easy to reach. 1 - connector control unit 2 - connector communication module 3 - connector network module 4 - connector power cord The operator is instructed not to connect any device to the optional connectors unless it possesses an...
  • Page 13: Preparation

    The Brachumera PFM is standard executed with an 3.5" display, since the Brachumera PFM standard comes with the Lode Ergometry Manager to control the ergometer and collect the PFM data. The 3.5" display only shows data (load, RPM and time) and cannot be used to steer the ergometer.
  • Page 14: External Control With Ecg Or Ergospirometry System

    (see for detailed instructions the user manual of your external device). 7.3 - External control with Lode Ergometry Manager Your device is enabled to communicate with the Lode Ergometry Manager (LEM). LEM gives the opportunity to work with a database, create protocols and to perform a variety of tests: 1.
  • Page 15: Exchange Parts Of The Brachumera

    8 - Exchange Parts of the Brachumera 8.1 - Exchange Handgrips/Pedals Based on the athlete or type of test it is possible to change handgrips. As long as the thread of the handgrip fits the cranks (standard size) you can attach the handgrip to the Brachumera crank.
  • Page 16: Change Crank Position

    8.2 - Change Crank Position The cranks of the Brachumera can be placed asymmetrical as well as symmetrical, depending on the sport of the participant. Always reposition the left crank left crank, leave the right side fixated on the Brachumera, in this case you always know the correct position of the left crank.
  • Page 17 The position of the cranks with a Brachumera PFM is very important. Please contact your local distributor if you want to change the cranks of the Brachumera PFM. M965911/21 / VERSION: 1.0 - 2019-09-30 17/26...
  • Page 18: Brachumera With Stand (965840)

    9 - Brachumera with Stand (965840) With the stand for the Brachumera, the Brachumera can be used in vertical position and the height of the Brachumera can be adjusted. This creates the possibility to easily set the height of the Brachumera needed for the participant.
  • Page 19: Brachumera Pfm (965921)

    In case your Brachumera is a Brachumera with Pedal Force Measurement (Brachumera PFM (965921)), you have to use the Lode Ergometry Manager (LEM) software to collect and analyse the PFM data. In the manual Manual LEM 10 PFM all information about the use of the PFM is described.
  • Page 20: Maintenance

    Opening of the equipment by unauthorized agencies is not allowed and will terminate any claim to warranty. Lode will make available on request circuit diagrams, component part lists, descriptions, calibration instructions, or other information that will assist authorized service personnel to repair those parts of the ergometer that are designated by Lode as repairable by authorized service personnel.
  • Page 21: Calibration

    The ergometer should be calibrated once a year. In case any damage is observed of the ergometer Lode B.V. or his representative should be informed in order to execute the necessary repair(s). Service of the ergometer is restricted to factory-trained personnel only.
  • Page 22: List Of Symbols Used

    14 - List of symbols used Read manufacturer’s guide, advises and instructions and manual Alternating Current IEC 60417-5032 The equipment has a safety earth (ground) connection and must be connected to an earthed (grounded) wall socket. Potential Equalization Conductor Caution "ON"...
  • Page 23 RS232 Network (Proprietary Lode) CE and notified body FCC 18 RF ISM tested Symbol for collection, treatment, recycling and disposal of waste electrical and electronic equipment (WEEE) as set out in Directive 2002/96/EC of 27 January 2003 of the European Parliament and of the Council on waste electrical an electronic...
  • Page 24: Accessories

    Control Unit cable Electric adjustable chair Adjustable sports Stand for new Adjustable wall fixation for arm ergometer cranks incl. pediatric Brachumera sport for Brachumera sport range Partnumber: 917813 Partnumber: 917813 Partnumber: 925818 Partnumber: 925818 Partnumber: 965840 Partnumber: 965840 Partnumber: 965830...
  • Page 25: Specifications

    Screen size (diagonal) 17.8 cm 7 inch Touchscreen Connectivity Control Unit with touch screen 7" for ergometer Lode interface protocol Ergoline P10 interface protocol Ergoline P4 interface protocol Schiller interface protocol Bosch EKG 506 DS interface protocol USB connector RS232 out connector...
  • Page 26 Power requirements V AC 100 - 240 V Phases Frequency 50/60 Hz Power consumption 160 W Power cord length 250 cm 98.4 inch Power cord IEC 60320 C13 with CEE 7/7 plug Standards & Safety IEC 60601-1:2012 ISO 13485:2016 compliant ISO 9001:2015 compliant Environmental conditions Minimum operational temperature...