Remote Frequency Selection; Emergency Frequency Selection - Garmin GTR 205 Pilot's Manual

Table of Contents

Advertisement

Remote Frequency Selection

FEATURE LIMITATIONS
Availability dependent upon configuration
On units configured for remote frequency recall, COM user frequencies are selectable
via a remote switch.
Pressing the switch once loads the next user frequency into the STBY window
Pressing the switch repeatedly scrolls through the list of presets
Some installations may have two dedicated recall switches: one to scroll up,
one to scroll down
Selections do not activate until transfered to active

Emergency Frequency Selection

Pushing and holding either the volume knob or Flip-Flop key for 0.5 seconds
provides a quick method for remotely tuning the emergency frequency
(121.50 MHz). This feature is available any time the unit is on, regardless of GPS
or display status.
Volume/Squelch Knob Shortcut
190-02766-02 Rev. A
Pushing and holding the volume knob for 0.5 seconds
automatically tunes the COM emergency frequency
(121.50 MHz).
"Hold for 121.50" control label appears in the
annunciator bar
Frequency automatically loads to the COM standby
window and then transfers to the active COM frequency