Spread Factor
If ADR is disabled, the device will send data via this spread factor.
If the device does not receive ACK packet from network server, it will resend
Confirmed Mode
data 3 times at most.
Reporting interval ≤ 30 mins: the device will send a specific number of
LinkCheckReq MAC packets to the network server every 30 mins to validate
connectivity; If there is no response, the device will re-join the network.
Rejoin Mode
Reporting interval > 30 mins: the device will send a specific number of
LinkCheckReq MAC packets to the network server every reporting interval to
validate connectivity; If there is no response, the device will re-join the
network.
Set the number of
When rejoin mode is enabled, set the number of LinkCheckReq packets sent.
packets sent
Allow network server to adjust datarate of the device. This only works with
ADR Mode
Standard Channel Mode.
Tx Power
Transmit power of device.
Note:
1) Please contact sales for device EUI list if there are many units.
2) Please contact sales if you need random App keys before purchase.
3) Select OTAA mode if you use Milesight IoT cloud to manage devices.
4) Only OTAA mode supports rejoin mode.
5) For -868M model, the default frequency is EU868; for -915M model, the default frequency is
AU915.

3.3 General Settings

Go to Device > Setting > General Settings of ToolBox App to change the reporting interval, etc.
Parameters
Reporting interval of magnet, tamper and battery level to network server.
Reporting Interval
Default: 1080mins, Range: 1 - 1080 mins
Note:
WS301 will also transmit alarm when magnet status is changed or
Description
10