Downlink Commands - LINOVISION IOT-S500DCS User Manual

Magnet contact switch
Hide thumbs Also See for IOT-S500DCS:
Table of Contents

Advertisement

When magnet or tamper status has changed.
Channel
01
03
04
Example:
Channel
Type
75
01
(Battery)
Channel
Type
00
04
(Tamper Status)

5.3 Downlink Commands

IOT-S500DCS supports downlink commands to configure the device. The application port is 85 by
default
.
Channel
ff
Example: Set reporting interval as 20 minutes.
Channel
ff
Type
75(Battery Level)
UINT8, Unit: %
00=>Switch close
00(Magnet Status)
01=>Switch open
00=>Device is installed
00(Tamper Status)
01=>Device is un-installed
01 75 64 03 00 00 04 00 01
Value
Channel
64 => 100%
Value
01
(Un-installed)
Type
03 (Set Reporting Interval)
ff03b004
Type
03 (Set Reporting
Interval)
-END-
Description
Type
00
03
(Magnet Status)
Description
2 Bytes, unit: s
Value
b0 04 => 04 b0 = 1200s
= 20 minutes
Value
00
(Close)