Technical documentation
Mass flue rate at nominal power
Mass flue rate at minimum power
CO
at nominal power
2
CO
at minimum power
2
CO at 0% of O
at nominal power
2
CO at 0% of O
at minimum power
2
No
at 0% of O
at nominal power
x
2
No
at 0% of O
at minimum power
x
2
Flue temperature at nominal power
Flue temperature at minimum power
NATURAL GAS (G20)
Heating
Heating
power
power
(kcal/h)
(kW)
20000
23,3
19000
22,1
18000
20,9
17000
19,8
16000
18,6
15000
17,4
14000
16,3
13000
15,1
12000
14,0
11000
12,8
10000
11,6
9000
10,5
8000
9,3
STEME ed 07/03

COMBUSTION PARAMETERS

(with combustion air temperature 15 ºC )
HEATING POWER ADJUSTMENTS
Burner gas
Burner nozzle
flow rate
pressure
(m
/h)
(mbar)
3
(mm H
O)
2
2,71
11,8
120
2,59
10,8
110
2,46
9,7
99
2,33
8,7
89
2,20
7,8
79
2,07
6,9
70
1,94
6,1
62
1,81
5,3
54
1,68
4,6
47
1,55
3,9
40
1,42
3,3
33
1,29
2,7
27
1,16
2,2
22
G20
kg/h
61
kg/h
64
%
5.96
%
2.3
ppm
61
ppm
103
ppm
100
ppm
70
ºC
117
ºC
95
BUTANE (G30)
Burner gas
Burner nozzle
flow rate
pressure
(kg/h)
(mbar)
(mm H
2,02
28,8
294
1,93
26,3
269
1,83
23,7
242
1,73
21,3
217
1,64
19,0
194
1,54
16,8
172
1,44
14,8
151
1,35
12,9
132
1,25
11,1
114
1,16
9,5
97
1,06
8,0
81
0,96
6,6
67
0,86
5,3
54
31
Technical documentation
G30
G31
60
62
64
66
7.0
6.7
2.7
2.6
86
55
112
102
187
144
70
91
119
116
96
96
PROPANE (G31)
Burner gas
Burner nozzle
flow rate
pressure
(kg/h)
(mbar)
O)
2
1,99
37,0
1,90
33,8
1,80
30,5
1,71
27,3
1,61
24,4
1,52
21,6
1,42
19,0
1,33
16,6
1,23
14,3
1,14
12,2
1,04
10,2
0,95
8,4
0,85
6,8
EOLO MINI
(mm H
O)
2
377
345
311
279
249
220
194
169
146
124
104
86
69