• Horizontal intake-exhaust kit Ø 80/125.
Kit assembly (Fig. 20): install the bend with flange (2) onto the
central hole of the boiler inserting the gasket (1) and tighten
using the screws in the kit. Fit the male end (smooth) of the
adapter (3) up to the stop on the female end of the bend (2) (with
lip seal). Fit the Ø 80/125 (4) concentric terminal pipe with the
male end (smooth) to the female end of the adapter (3) (with lip
gasket) up to the stop; making sure that the internal wall sealing
plate and external wall sealing plate have been fitted, this will
ensure sealing and joining of the elements making up the kit.
Normally the horizontal intake/exhaust kit Ø 80/125
is used if particularly long extensions are required
• Extensions for horizontal kit. The Ø 80/125 horizontal intake-ex-
haust kit can be extended up to a max. horizontal distance of
7,300 mm including the terminal with grid and excluding the
concentric bend leaving the boiler and the adapter Ø 60/100 in
Ø 80/125 (Fig. 21). This configuration corresponds to a resist-
ance factor of 100. In these cases the special extensions must be
requested.
When installing the ducts, a section clamp with pin
must be installed every 3 metres.
2
3
1
20
4
5 6
The kit includes:
N°1 - Gasket (1)
N°1 - Concentric bend Ø 60/100 (2)
N°1 - Adapter Ø 60/100 for
Ø 80/125 (3)
N°1 - Concentric terminal
int./exh. Ø 80/125 (4)
N°1 - Internal wall sealing plate (5)
N°1 - External wall sealing plate (6)
C
12
20
Max. 7300
Max. 7195