Graco 243701 Instructions And Parts List

Graco 243701 Instructions And Parts List

Heated header and manifold
Hide thumbs Also See for 243701:

Advertisement

Quick Links

Instructions - Parts List
Heated Header and
Manifold
Used to dispense non-flammable hot melt sealants and adhesives. For professional use
only.
Heated Header with Inlet Dispense Valve
Model 243701
3500 psi (241 bar, 24.1 MPa) Maximum Fluid Pressure
400°F (204°C) Maximum Temperature
150 psi (10.3 bar, 1 MPa) Maximum Air Control Pressure
240 Volt, 50/60 Hz, 500 Watts/Header, 200 Watts/Inlet Valve
For use with Therm-O-Flow Plus drum unloader systems
Heated Distribution Manifold
with Inlet Check Valves and Outlet Shut-Off Valves
Model 243697
3500 psi (241 bar, 24.1 MPa) Maximum Working Pressure
400°F (204°C) Maximum Temperature
240 Volt, 50/60 Hz, 400 Watts
For use with Therm-O-Flow Plus drum unloader systems
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Model 243701 Shown
309181H
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 243701 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graco 243701

  • Page 1 3500 psi (241 bar, 24.1 MPa) Maximum Working Pressure 400°F (204°C) Maximum Temperature 240 Volt, 50/60 Hz, 400 Watts For use with Therm-O-Flow Plus drum unloader systems Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Model 243701 Shown...
  • Page 2: Table Of Contents

    Graco Standard Warranty ....16 Graco Information ......16...
  • Page 3: Warnings

    Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 4 Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
  • Page 5: Unpacking And Repacking

    Repairing and Repacking the Product Your header with dispense valves was carefully pack- aged for shipment by Graco. When the package arrives, When the header with dispense valves requires service, perform the following procedure to unpack the units: it is the purchaser’s responsibility to have the unit repaired.
  • Page 6: Installation

    NOTE: The heated inlet valve and heated header pipe, and the heated distribution manifold are designed to be used with Graco’s Therm-O-Flow Plus controls. Two 1. Connect the heated hose inlet to the 1/2” npt(f) heat zones are required for the header assembly. The tapered pipe thread dispense valve inlet.
  • Page 7: Operation

    Operation Operation Model 243701 Header The inlet valve is “air to open” and “air to close” valve. This valve must be operated by a 4–way solenoid valve. Four–way solenoids with a 24” (60 cm) and high tem- perature air tubes are listed in Accessories on page 13.
  • Page 8: Parts

    Parts Parts Model 243701 Header with Dispense Valve 15, 24 2, 11, 17 309181H...
  • Page 9 Parts Ref. Part Description Qty. Ref. Part Description Qty. C57886 BRACKET, connector 94/0545/99FITTING, plug, 1/8 NPT 115861 BULKHEAD, housing C19269 SCREW, mach, slotted, H C20865 BUSHING, conduit 115862 CONNECTOR, male, crimp C20715 FITTING, locknut, cond C50019 TERMINAL, ring 196729 MANIFOLD, weldment C19758 SCREW, machine, binding C32325...
  • Page 10: Heated Manifold, 230V

    Parts Heated Manifold, 230V 10, 11 1” NPT(F) REF. (2) PLACES 3/4” NPT(F) REF. (2) PLACES 6, 7 1, 2, 3 25, 26 309181H...
  • Page 11 Parts Ref. Part Description Qty. Ref. Part Description Qty. 115860 INSERT, male C08022 SPACER 115861 BULKHEAD, housing, insulating C32255 SENSOR, temperature 115862 CONNECTOR, male, crimp 115937 HEATER, cartridge, C19269 SCREW, mach, slotted hd 3/8 dia x 6 lg C34043 BRACKET C56199 HOUSING, manifold C19800...
  • Page 12: Dimensions

    Dimensions Dimensions Model 243701 Heated Header Clearance Dimensions Inlet Control Valve Manual Bleed Valve O2.0” (5 cm) Drip Shut–off Valve (typ.) (1.0) (6.67) TYP.* (40.0) (42.0) (45.0) *Optional outlet ports (3) between each pair of valves shown. TI0375 Model 246697 Heated Distribution Manifold Mounting Dimensions 7.75”...
  • Page 13: Accessories

    Accessories Accessories Heat Zone Control Boxes 243698 2 Zone Control [(1) 16 socket outlet connection] 243699 4 Zone Control [(2) 16 socket outlet connections] These controls are 220/440 Volt, 50/60 Hz and support up to 1250 watts per zone. Cables 15’...
  • Page 14: Technical Data

    Distribution manifold 8 Pin Socket Voltage (both) 240 Volt, 50/60 Hz Wattage Inlet valve 200 watts Header 500 watts Distribution manifold 400 watts These electrical connections match the 8 socket connectors on the end of Graco 230 volt heated hoses. 309181H...
  • Page 15 Technical Data 309181H...
  • Page 16: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

243697