Start-Up Procedure - Waterworld New Millennium Installation & Service Manual

5-stage reverse osmosis drinking water system with booster pump
Table of Contents

Advertisement

1) Check to see all connections are made
2) Check that the pre-filter and pre-carbon sumps are secure with o-rings in place using
the housing wrench provided.
3) Slowly turn on the water by turning the needle valve counterclockwise or ball valve 1/4
turn,where handle is parallel to the tubing line.
4) The valve handle on top of the tank should be in the open position, parallel to the
valve body.
5) The handle of the faucet should be in the closed position.
6) Check for leaks.
7) The Millennium® drinking water system makes 2 gallons of drinking water per hour and
requires 2 hours before water is readily available.
8) During this initial fill period, you will hear water being discharged through the red drain
line. This is normal as the contaminated water is being rejected by the reverse
osmosis membrane.
The Millennium® RO system comes with a manual flushing valve on the drain line. This must
be closed during normal operation.
WARNING: DO NOT DRINK WATER FROM THE FIRST TANK PRODUCED BY THE
SYSTEM. COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET.
DISCHARGING MIGHT TAKE UP TO 15 MIN.
If you have any difficulties with the installation, or require additional information on your
Millennium® RO system please consult your local dealer.
We thank you for purchasing our Millennium
to maintain high quality pure water, it is important that scheduled maintenance be followed.
START UP PROCEDURE
reverse osmosis drinking water system. In order
®