1) Check to see all connections are made
2) Check that the pre-filter and pre-carbon sumps are secure with "O" rings in place using the
housing wrench provided.
3) Slowly turn on the water by turning the needle valve counterclockwise or ball valve 1/4 turn,
where handle is parallel to the tubing line.
4) The valve handle on top of the tank should be in the open position, parallel to the valve
body.
5) The handle of the faucet should be in the closed position.
6) Check for leaks.
7) The Millennium
requires 2 hours before water is readily available.
8) During this initial fill period, you will hear water being discharged through the red drain
line. This is normal as the contaminated water is being rejected by the reverse osmosis
membrane.
The Millennium system comes with a manual flushing valve on the drain line. This must be
closed during normal operation.
Remember to connect the transformer for the booster pump to a dedicated GFI electrical
outlet.
CAUTION: ALWAYS CONSIDER ELECTRICAL SHOCK HAZARD WHEN WORKING WITH
AND HANDLING ELECTRICAL EQUIPMENT. IF UNCERTAIN, CONSULT AN ELECTRICIAN.
ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL
AND STATE ELECTRICAL CODES.
WARNING: DO NOT DRINK WATER FROM THE FIRST TANK PRODUCED BY THE
SYSTEM. COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET.
DISCHARGING MIGHT TAKE UP TO 15 MIN.
If you have any difficulties with the installation, or require additional information on your unit please
consult your local dealer.
We thank you for purchasing our Millennium
to maintain high quality pure water, it is important that scheduled maintenance be followed.
1) Sediment Pre-filter: The Pre-Filter protects the system and should be maintained
regularly. The Pre-Filter should be changed when the outside discolors to a cardboard
brown color and before the inner core discolors. The life of the Pre-Filter will depend
upon condition of your water supply and should be checked at 3 month intervals until
a filter life is established (average life 6 months). Always make sure that o-rings are
seated properly inside sumps before tightening canisters.
2) GAC & Carbon Block: Designed to remove chlorine from the water supply, as well as
organic and inorganic substance before entering the TFC membrane (average life 12
months).
Always make sure that o-rings are seated properly inside sumps before tightening
canisters.
3) Post-Carbon: The post-filter should be changed when you experience an unusual taste
and/or odor to the water and has a nominal life of 1 year.
4) Membrane: The high quality Thin Film Composite membrane should last between 2 to 4
years depending on the quality of your local water & water usage.