Waterworld New Millennium Installation & Service Manual page 6

5-stage reverse osmosis drinking water system with booster pump
Table of Contents

Advertisement

(Using the water supply adaptor Part # JGV-ASVPP1LF)
NOTE: The Millennium® RO system must be connected to the COLD water
supply only.
1) Turn off the cold water supply to the sink faucet by locating the round or oblong handle
and turning clockwise until the water supply is off.
NOTE: If the cold water shut off valve fails to turn off the water, the house supply can be
turned off at the main water supply.
2) The water supply adapter may be installed at the faucet connection
3) Disconnect the 3/8" flex line from the base of cold water basin supply angle stop valve.
4) Re-connect the 3/8" JGV-ASVPP1LF Angle Stop Valve to the basin supply angle
stop valve.
Green tubing going
towards RO
JGV-ASVPP1LF Angle Valve
5) Re-connect flex line to the JGV-ASVPP1LF Angle Supply Valve.
6) Push green tubbing in to Quick Connect fitting up to tube stop. Pull on the tubing to
check it is secure. Test the system before use.
NOTE: All local plumbing codes must be followed to ensure proper installation and use of
your system.
CAUTION: A pressure regulator is recommended for feedwater pressure above 80psi.
TAPPING INTO THE COLD WATER LINE
For flex metal or plastic line.
Quick Connect
Flex metal or plastic line
going towards sink faucet
3/8 Compression thread
3/8 Compression thread
Cold water basin supply
angle stop valve
5