Conditions For Operation - Waterworld New Millennium Installation & Service Manual

5-stage reverse osmosis drinking water system with booster pump
Table of Contents

Advertisement

Congratulations on the purchase of your WW-USA Water System. WW-USA warrants that the Products identified below are
free from material defects in materials and workmanship. Any defective part will be replaced at no charge for the part if any fail-
ure caused by the defect occurs within the following time periods originating from the date of original system installation. This
Limited Warranty does NOT include freight or labor charges. To place your system under this Limited Warranty, you or your
authorized WW-USA dealer must register your equipment with WW-USA within 30 days of the installation date. For service
under this Limited Warranty, contact your authorized WW-USA dealer. Retain your receipt along with this Limited Warranty for
reference if service is necessary.
The Millennium® reverse osmosis system is warranted to be free from defects in materials and workmanship under normal
use within the operating parameters listed below. For a period of five years from the date of purchase Millennium® will repair or
replace any part of the reverse osmosis system with the exception of the filters and electrical components if any.
CONDITIONS OF WARRANTY:
Millennium® assumes no responsibility for incidental or consequential damages; for damages arising out of misuse of the
product or the use of any unauthorized attachment; for damages resulting from improper installation or for damages resulting
from the use of the product with a defective plumbing system.
In no event shall Millennium® be liable for any direct, indirect, special, punitive, incidental, exemplary or consequential dam-
ages, attorney's fees or any damages whatsoever, even if Millennium® has been previously advised of the possibility of such
damages, whether in an action under contract, negligence, or any other theory, arising out of or in connection with the use,
inability to use, or performance of the Millennium® system.
Millennium® is not responsible or liable for damage to any part of the Millennium® system because of misuse; misapplication;
negligence; alteration; accident; installation; neglect; misapplication; physical damage; fouling and/or scaling of the membrane
by minerals; sediment; bacterial attack; or operation contrary to our instructions, incompatibility with accessories not autho-
rized for use with the system, or damage caused by freezing, flood, fire, or Act of God.
In no event shall Millennium® its subsidiaries or affiliates, or their respective officers, directors, employees, representatives,
dealers or agents be liable for special, incidental, consequential, punitive, indirect, or other special damages, including but not
limited to, loss of data, use, or profits, however caused, whether for breach of contract, negligence or otherwise, and whether
or not Millennium® has been advised of the possibility of any such damages.
Millennium® assumes no warranty liability in connection with this reverse osmosis system other than that specified herein.
This warranty is in lieu of all other warranties, expressed or implied, including warranties of fitness for a particular purpose.
WARRANTY SERVICE:
Millennium® will provide warranty service under the following conditions:
1)
Contact your local dealer who will obtain return authorization instructions.
2)
Ship the unit or part freight prepaid for warranty evaluation or service with RMA # written on package.
Systems or parts covered under the warranty shall be repaired (or, at our option replaced) and returned
without charge.
Operating Parameters:
System Pressure
Temperature
pH Range
Maximum feed TDS level
Maximum Turbidity
Chemical Parameters:
Maximum Hardness
Maximum Iron (Fe)
Maximum Manganese (Mn)
Maximum Hydrogen Sulfide (H2S)
Maximum Chlorine (Cl2)
*A pressure regulator is recommended for feedwater pressure above 80 psi.
MILLENNIUM® LIMITED WARRANTY

CONDITIONS FOR OPERATION:

14
40-80psi*
4-38 C (39-100 F)
3.0 to 11.0
2000 ppm
1.0 Net Turbidity (NTU)
350mg/L (20 gpg)
0.1 mg/L
0.05 mg/L
0.00 mg/L
2.00 mg/L