Supplies 20 Valcom power units for
powering Valcom one-way amplified
speakers (1 Amp -24VDC); Additional power
supplies are required for a quantity of
speakers using over 20 power units
•
Page with music outputs (2 provided); music
mutes during page
•
Page without music output
•
Battery backup input (Use Valcom VPB-260
battery backup supply)
•
Time clock/single tone (Contact closure
activated)
•
Night ring/warble tone (Closure or 90VAC
activated)
Priority sequence of tones:
Page overrides music
Night ring mixes with music and page
Time clock mixes with music and page
•
Individual switches for selection of night ring
and time clock tones per output
•
May be used with 25 or 70 Volt amplifiers
•
AC powered, 115 or 230VAC
•
Internationally recognized power connector
•
AC input fused at 1 Amp @ 115VAC, 60Hz
or 0.5 Amp @ 230VAC, 50Hz
•
115/230 Volt selector switch for international
use
•
UL listed
Dimensions/Weight
•
7.06"H x 9.00"W x 2.40"D
(17.93cm H x 22.86cm W x 6.10cm D)
•
Weight: 3.7 lbs. (1.68 kg)
Nominal Specifications
Input Impedance:
Input Level:
Voice Switch Sensitivity:
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level:
Output Impedance:
Output Level:
DC Output:
Nominal Power Requirements
Voltage:
Current:
115VAC
1.0 Amp
230VAC
0.5 Amp
Battery Backup
The V-2001A is equipped with a standard
3-prong polarized MOLEX connector to allow
connection of a fused output (3 Amp) battery
backup supply (Valcom VPB-260 or equivalent)
in case of AC power failure. Backup time will be
a function of system usage.
600 Ohms
-10dBm nominal
-21dBm
-10dBm nominal
8 Ohms
-10dBm nominal
1 Amp at -24VDC
2
•
Use a cord set consisting of a minimum 18
AWG cord and grounding type attachment
plug rated a minimum of 15A, 250V. The
cord set should have the appropriate safety
approvals for the country in which the
equipment will be installed and should be
marked HAR.
•
The socket outlet shall be installed near the
equipment and shall be easily accessible.
NOTE: The AC line cord of the VPB-260 and
the AC line cord of the V-2001A should be
plugged into the same AC circuit.
Environment
Temperature:
Humidity:
0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in
this manual is the customer premise
equipment such as an electronic key system,
a PABX or a dedicated single line
telephone(s). The V-2001A is not intended
for direct or indirect connection to the public
telephone network or to PABX analog station
ports. When used with a customer premise
telephone system such as a key system
or PABX system, these units are interfaced
to the system via a fully protected page port
or system central office port, which is a fully
protected interface device. Also, the host
system must be configured to disallow
central office trunk conferencing in order to
prevent indirect connection to the public
network.