Maximum Settings Of Overload Relay, Circuit Breaker And Fuses; For Ga55/Ga55 W; For Ga75/Ga75 W; For Ga90C/Ga90C W - Atlas Copco GA55 Instruction Book

Stationary air compressor
Hide thumbs Also See for GA55:
Table of Contents

Advertisement

7.3 Maximum settings of overload relay, circuit breaker and fuses

7.3.1 For GA55/GA55 W

Supply
Frequency
voltage
(V)
230
50 Hz - IEC
400
50 Hz - IEC
500
50 Hz - IEC
220-230
60 Hz - IEC
220-230
60 Hz - CSA/UL
440-460
60 Hz - IEC
440-460
60 Hz - CSA/UL
575
60 Hz - IEC
575
60 Hz - CSA/UL
7.3.2

For GA75/GA75 W

Supply
Frequency
voltage
(V)
230
50 Hz - IEC
400
50 Hz - IEC
500
50 Hz - IEC
220-230
60 Hz - IEC
220-230
60 Hz - CSA/UL
440-460
60 Hz - IEC
440-460
60 Hz - CSA/UL
575
60 Hz - IEC
575
60 Hz - CSA/UL
7.3.3

For GA90C/GA90C W

Supply
Frequency
voltage
(V)
230
50 Hz - IEC
400
50 Hz - IEC
500
50 Hz - IEC
220-230
60 Hz - IEC
220-230
60 Hz - CSA/UL
380
60 Hz - IEC
32
Circuit breaker
Overload
Q15 11)
relay F21
(A)
(A)
8.3
124
4.8
71
3.8
57
8.3
123
8.3
123
4.6
61
4.6
57
3.7
47
3.7
45
Circuit breaker
Overload
Q15 11)
relay F21
(A)
(A)
8.3
160
4.8
92
3.8
74
8.3
165
8.3
165
4.6
82
4.6
77
3.7
63
3.7
61
Circuit breaker
Overload
Q15 11)
relay F21
(A)
(A)
12.5
184
7.3
106
5.8
85
14
190
14
190
7.6
112
Fuses
Fuses
CSA HRCII-C
(A)
(A)
250
-
160
-
125
-
250
-
-
200
125
-
-
100
100
-
-
80
Fuses
Fuses
CSA HRCII-C
(A)
(A)
315
-
200
-
160
-
300
-
-
300
150
-
-
150
125
-
-
125
Fuses
Fuses
CSA HRCII-C
(A)
(A)
355
-
250
-
200
-
400
-
-
400
250
-
Instruction book
Fuses
UL Class K5
(A)
-
-
-
-
200
-
100
-
70
Fuses
UL Class K5
(A)
-
-
-
-
300
-
150
-
100
Fuses
UL Class K5
(A)
-
-
-
-
400
-
2920 1381 02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga75Ga55wGa75wGa90cGa90cw

Table of Contents