KEY:
Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
NOTE: Recommended pump speed for continuous operation
(to shaded area): 60 cpm
psi
cycles/min.
bar
MPa
18
6000
420
42
5000
350
35
A
4000
280
28
B
3000
210
21
2000
140
C
14
1000
70
7
0
0
1
gpm
liters/min.
3.8
FLUID FLOW
(TEST FLUID: NO. 10 WEIGHT OIL)
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/
gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Technical Data
Model 237707 King Pump
scfm
m#/min.
35
52
60
68
300
8.40
250
7.00
200
5.60
A
150
B
4.20
100
C
2.80
50
1.40
2
3
4
7.6
11.4
15.2
A
0.6 MPa, 6.3 bar (90 psi) Air Pressure
B
0.5 MPa, 4.9 bar (70 psi) Air Pressure
C
0.3 MPa, 2.8 bar (40 psi) Air Pressure
psi
bar
cycles/min.
MPa
18
6000
420
42
5000
350
35
4000
A
280
28
3000
B
210
21
2000
140
14
C
1000
70
7
0
0
1
gpm
liters/min.
3.8
(TEST FLUID: 4 MILLION CPS
WELDABLE RUBBER BASE SEALER)
To find Pump Air Consumption (m#/min. or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (gray). Follow right to scale to read air consumption.
35
52
60
68
A
B
C
2
3
7.6
11.4
15.2
FLUID FLOW
308355
scfm
m#/min.
300
8.40
250
7.00
200
5.60
150
4.20
100
2.80
50
1.40
4