6-3. CASSETTE DECK SECTION ADJUSTMENT (Refer to Fig. 6-1 and Fig. 6-2)
| .
Frequency
Response
Normal Blank
tape
1,000 Hz, 10,000 Hz
30 mV
Recording
SVR601
(Left)
SVR602
(Right)
REC/P.B
NOTE:
1. Use the Maxell UD C-60 for Adjustment step 3 and 4.
2. As the test tape has been changed, set to 180 mV when using 333 Hz test tape. For details, refer to Service
Guide (No. 0012) issued in Nov., 1982.
SERVICE MANUAL
AC-M2
1,000 Hz to
10,000 Hz
flat
Adjustment
Test Tape or
Adjustment
Result
Rewcke
Item
Supply Signal
Point
Playback
333 Hz
SVR301
180 mV
e Connect a AC Voltmeter
1
es i
or
(Left)
between TP-15 (Left),
(Se ces 2)
315 Hz
SVR302
190 mV
TP-16 (Right) and TP-14
vies
Test Tape
(Right)
(GND).
e Set Beat Switch to
Bias
Position 2.
2
Esscteac
L603
85 kHz
e Connect a Frequency
meq
y
Counter between TP-17
and TP-18 (GND).
=|
|
e TR611 (28C2236) Base
to GND.
Wainer Blank
SVR303
e Tape Selector Switch to
3
Recording
ne
(Left)
0.4mvV
Normal position.
Level
1.000 ns 300mV
SVR304
:
e Connect a AC Voltmeter
:
(Right)
between TP-11 (Left),
TP-12 (Right) and TP-13
(GND).
e Set Tape Selector Switch
to Normal position.
e Connect a AC Voltmeter
between TP-15 (Left),
TP-16 (Right) and TP-14
(GND).