Introduction; Boiler Description; Safety Precautions; Important Informations - Centrometal PelTec-Compact Technical Instructions

Table of Contents

Advertisement

Introduction, boiler description, safety precautions, important informations

1.0. INTRODUCTION

The PelTec-Compact has a modern construction and design and is made out of the controlled
materials of high quality, welded with most modern technology and is approved and tested under EN
303 - 5 norm and fulfill all special request for the connection on the installation of a central heating
system.

1.1. BOILER DESCRIPTION

Steel hot water boiler are engineered for wood pellet firing. In the boiler is installed the burner for wood
pellet firing with the automatic firing and automatic self-cleaning function which enables the reliable
operation also with the low quality wood pellets. The function of the automatic cleaning flue gas tubes
provides the unifying exchange of the heat and high and unifying level of boiler efficiency. Digital boiler
controller in a basic construction offers also the possibility of control with the lambda probe or level
control of the wood pellets in the pellet tank. The pellet tank is the integral part of the boiler. The boiler is
delivered in pieces due to the easier transport into the boiler room.

1.2. SAFETY PRECAUTIONS

The boiler and related accessories are state of the art and meet all applicable safety regulations.
The control unit, wiring chamber, el. heater, safety cut-out STB thermostat, fan, grid cleaning
mechanism, flue gas tubes cleaning mechanism and pellet supply mechanism are integrated into the
PelTec-Compact. They are operate at a voltage of 230 V AC. Improper installation or repair can pose
the danger of life-threatening electric shock. Installation may beperformed only by appropriately
qualified technicians.
Caution symbols:
Please take careful note of the following symbols in this Operating Manual.
This symbol indicates measures for protection against accidents and warning
for the user and / or exposed persons.

1.3. IMPORTANT INFORMATIONS

All local regulations, including those referring to national and European standards need to be complied
with when installing the appliance.
The boiler must not be modified unless using the tested original accessories we provide or if the work is
undertaken by our Customer Service.
Only fit original spare parts. These can be obtained from your customer service partner or directly from
ourselves. European standards need to be complied with when installing the appliance.
Regular care and cleaning of the appliance, flue gas outlets, connecting piece and flue.
CAUTION:
The flue may block if the boiler is heated again after a long period of it not being used. Before starting
the boiler, have the flue checked by a specialist (chimney sweep).
Ensure sufficient supply of fresh air in the installation room when heating. The air must be replaced at
least 0.8 times an hour through constant and reliable room venting. Fresh air may have to be provided
from outside if the windows and doors in the room where the boiler is installed are well sealed or if this
room contains other equipment, such as extractor hoods, clothes dryer, fan etc.
Technical instructions PelTec-Compact
9

Advertisement

Table of Contents
loading

Table of Contents