Midea CE-BD240-FT Service Manual page 24

Table of Contents

Advertisement

Service Manual_2018-V1.0
7)Use the wrench to remove the bolts by
steps❹❺❻❼, replace the compressor and reverse
process can complete installation.
8)Use Pipe cutter cut off the condenser tube❽, then
Shear off capillary ❾ by the capillary tube scissors.
9)Replace the compressorand welding the compressor
pipeline.-❿Welding the process pipeline.-⓫Welding the
low-pressure muffler.-⓬Welding the high-pressure
exhaust pipe.
10)Replace the filter, Cu-Fe tubes welding ⓭ used Ag
welding rod, Cu-Cu tubes welding ⓮ used Cu welding
rod.