Intended Use; Electrical Power Requirements - HARVEY HW110S-36G Instruction Manual

Dovetail cabinet table saw
Table of Contents

Advertisement

3.4 Intended Use

This table saw and the workpiece guide equipment
supplied with it are intended to be used exclusively
for the following purposes:
Laminated and unlaminated board materials (e.g.
chipboard, coreboard, MDF board, ...)
Solid wood 
Gypsum plasterboard, Cardboard, Veneer with a
suitable clamping device
Dimensionally stable plastics (thermoset plastics,
thermoplastics).
Tools:
The chosen saw blade must be suitable both for the
specific work cycle and for the specific material.
Only circular blades which are solid chrome
vanadium (CV) or tungsten carbide tipped (TCT) and
have a diameter of 254mm (10"), arbor size of
15.875 mm (5/8") or 30mm, as well as a maximum
mounting width of 20.3 mm are allowed for the main
saw.
Site of installation / use:
The machine is not suitable for use outdoors, or in
rooms that are subject to moisture or the risk of
explosions.
The intended use of the machine involves
connection to a suitably dimensioned dust extraction
system .
Intended use also involves compliance with our
specified
operating,
conditions and the safety information contained in
the operating instructions.
The table saw may only be used, set up and
maintained by persons who are familiar with the
machine and aware of the dangers.
The pertinent accident prevention regulations as
well as any other generally recognized technical
safety and industrial health rules must be observed.
Repair work must be carried out by our own
customer service or by an authorized repair center.
Only original spare parts are allowed to be used on
this machine. We will assume no warranty for any
damage that is caused by using non-original spare
parts.
maintenance
and
The machine is prohibited from being used in a
potentially explosive atmosphere!

3.5 Electrical Power Requirements

List of the motor usage & pre-wired voltage
Item
Voltage(V)
Phase
Freq.( Hz)
Current A
Pre-Wired
Cords
Circuit Break
To avoid the accidental injury and damage to the
machine, please check the name plate of the
machine carefully to identify the power supply
demand of the machine.
The Circuit Breaker with RCD module (30mA) shall
be installed for supplying electric power to this
machine, in order to protect people against
electrical shock due to indirect shock。
repair
.
6
Motor
3 HP
4 HP
230 V
230 V
1 PH
1 PH
50/60 Hz
60 Hz
12 A
16 A
220 V/1 PH
220 V/1 PH
3
3
20A
4 kW
380 V
3 PH
50/60 Hz
8.3 A
380 V/3 PH
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hw110s-36pgHw110s-52gHw110s-52pg

Table of Contents