Staff Qualification; Intended Use; Inadmissible Use; Protective Measures For Users - Becker O 5.10 Operating Instructions Manual

Rotary vane-vacuum pump
Table of Contents

Advertisement

7 |
O 5.10, O 5.16, O 5.21, O 5.25, U 5.40
2.4

STAFF QUALIFICATION

Certain activities require a specific qualification to be demonstrated by the personnel carrying them out. The
following table summarises these qualifications:
Activity
Commissioning
Maintenance & Servicing
Disassembly
Operation
Symbol "x" approved personnel
Table 2.4: Staff qualification
2.5

INTENDED USE

The operational safety of the pump is only guaranteed if it is used as intended. Intended use also includes observing
these operating instructions for this product and any components, as well as carrying out all maintenance and service
work.
The pump may only be used as intended in accordance with the machine description and the technical data.
The intended use is summarised below:
• The pump evacuates air to a vacuum according to chapter 9.2
• The pumping of any other gases, especially hazardous substances, is not permitted and prohibited.
• The permissible technical parameters must be observed.
• The pump must not be operated in potentially explosive atmospheres.
• The pump must be protected from the weather.
• For any operation outside the technical parameters specified in the product data sheet, the manufacturer must
be consulted.
ATTENTION
Only use the pump for its intended purpose and only use it if it is in perfect working order! This is the only
way to ensure the operational safety of the pump!
2.6

INADMISSIBLE USE

• evacuating hazardous materials, especially flammable, explosive or toxic gases
• use in potentially explosive atmospheres (explosive gas/vapour/mist/air mixtures or dust/air mixtures or hybrid
mixtures of air and flammable substances).
• the use of the pump in non-commercial applications
• the operation of the pump in an incompletely assembled state
• operation with back pressures on the outlet side above the permissible parameters according to the product
data sheet (9.2)
2.7

PROTECTIVE MEASURES FOR USERS

When working on the pump, personal protective equipment must be worn to minimise health hazards.
The necessary protective equipment for the respective work must be worn at all times during work.
Personal protective equipment instructions posted in the work area must be followed.
WARNING
Risk of injury to hands due to crushing, cutting and high temperatures
During all work on the pump, hand protection must be worn in accordance with the glove schedule.
WARNING
Risk of injury to feet from crushing and falling objects
Foot protection must be worn during all activities at the pump.
Instructed persons with specialist
training
x
x
x
People
Instructed operating personnel
x

Advertisement

Table of Contents
loading

This manual is also suitable for:

O 5.16O 5.21O 5.25U 5.40

Table of Contents