MAINTENANCE INTERVALS
The following overview shows the maintenance intervals:
NOTE
First oil change / oil filter change after 500 operating hours. Thereafter as indicated in the maintenance
table.
O 5.10, O 5.16, O 5.21, O 5.25, U 5.40
Component
Intake filter (1)
Suction strainer
(4)
Gas ballast valve
filter (5)
Housing
General
overhaul
Air
Effluent
Element (LEE) (3)
Protective
devices
Oil (2)
Check level
Table 8.3: Maintenance intervals 1
40 h
40 - 200 h
(switch), check,
clean
clean
Visual inspection
1500 h (min.
6000 h
2x/1a)
clean
change
change
change
20000 h (min.
1x/5a)
execute