33 |
O 5.10, O 5.16, O 5.21, O 5.25, U 5.40
NOTE
wear suitable PPE.
NOTE
For a description of the safety instructions, see chapter 2.9
The entire pump must be cleaned at regular intervals depending on the amount of dust. This includes cleaning all
surfaces of the pump with a compressed air gun and moistened cleaning cloth.
The cleaning instructions of the manufacturers of components and assemblies are to be observed
The use of solvents or cleaning agents containing solvents is prohibited.
The use of cleaning agents that are highly flammable or generally flammable is prohibited!
The legal regulations for environmental protection must be observed during cleaning.
Restarting the pump is only permitted if there is no damage to the pump and no person is exposed to danger.
8.10 DISMANTLING AND DECOMMISSIONING
DANGER
Danger to life due to unexpected start-up
DANGER
Danger to life from electric shock - Personnel qualification
WARNING
Risk of injury from slipping, tripping and falling
WARNING
Danger from hot components and equipment
CAUTION
Contamination and damage to the environment by operating materials
NOTE
wear suitable PPE.
NOTE
For a description of the safety instructions, see chapter 2.9
The following steps must be observed during dismantling and decommissioning:
1.
Switch off the pump and release the drive.
2.
Switch off the power supply and secure it against being switched on again unintentionally.
3.
Disconnect the supply line of the drive.
4.
Shut off media lines and divert pressure differences if necessary.
5.
Disconnect the media lines from the pump.
6.
Disassemble the pump in reverse order of assembly or according to separate disassembly instructions. Loose
parts must be secured to prevent them from tipping over or falling down.
7.
Protect the pump from further contamination
8.
Clean the pump thoroughly and remove operating materials
9.
Dispose of operating materials in accordance with the applicable local regulations.
8.11
STORAGE
The following requirements for the storage location must be observed during storage in order to store the unused
pump in a proper condition over a longer period of time. If the following requirements are not observed, damage to
the pump may occur. Storage is recommended without oil filling. The storage location must be
• the storage place must be dry and clean
• the storage place must be level
• the storage place must be protected from sudden changes in temperature and humidity
• the storage location must be protected from salt spray, industrial gases, corrosive liquids, rodents and fungal
attack
8.12 DISPOSAL
CAUTION
Contamination and damage to the environment by operating materials