Scandomestic IC306D Manual page 17

Ice cream freezer
Table of Contents

Advertisement

Available languages

Available languages

Test room
Min temperature
Climate
and relative
class
humidity
A
16℃/80%
B
16℃/80%
C
16℃/80%
The climate class is indicated on the type plate.
This appliance is intended to operate in climates where the
temperature and the humidity range from 16°C/80%RH to
35°C /75%RH (climate class B).
Temperature class acc to EN 16901
Warmest M-package
Class
temperature colder
or equal to
C1
-18
C2
-7
The temperature class is indicated on the type plate.
FOR THE Supermarket
CABINETS:
Climate class acc to EN/ISO 23953-2
Dry bulb
Test room
temperature
Climate class
/℃
0
20
1
16
8
24
2
22
3
25
4
30
6
27
5
40
7
35
The climate class is indicated on the type plate.
Temperature class acc to EN/ISO 23953-2
Highest temperature-
Class
of warmest M-Test
gelato tubs/℃
L1
-15
L2
-12
Max temperature
and relative humidity
30℃/55%
35℃/75%
40℃/40%
Warmest M-package
maximum
temperature rise
allowed/K
2
2
Relative humidity/%
50
80
55
65
60
55
70
40
75
Highest minimum
temperature of all Test
tubs/℃
-18
-18
L3
-12
The temperature class is indicated on the type plate.
REMARK: The supermarket cabinets can also be used to
store and display packaged ice cream and other frozen
desserts.
FOR THE Scooping CABINETS:
Climate class acc to EN 16838
Test room
Dry bulb
Climate class
temperature/℃
0
20
1
16
8
24
2
22
3
25
4
30
6
27
5
40
7
35
The climate class is indicated on the type plate.
Temperature class acc to EN 16838
Highest
temperature-of
Class
warmest M-Test
gelato tubs/℃
L1
-15
L2
-12
L3
-12
The temperature class is indicated on the type plate.
-15
Relative
humidity/%
50
80
55
65
60
55
70
40
75
Highest minimum
temperature of all
Test tubs/℃
-18
-18
-15

Advertisement

Table of Contents
loading