Advantech ASMB-622 User Manual
Advantech ASMB-622 User Manual

Advantech ASMB-622 User Manual

Dual lga 4189 intel® xeon® scalable proprietary server board with 16 ddr4, 4 pcie x16, 3 pcie x8, 1 pcie x4, 5 sata3, 6 usb3.0, ipmi
Hide thumbs Also See for ASMB-622:
Table of Contents

Advertisement

Quick Links

User Manual
ASMB-622
Dual LGA 4189 Intel® Xeon®
Scalable Proprietary Server
Board with 16 DDR4, 4 PCIe x16,
3 PCIe x8, 1 PCIe x4, 5 SATA3, 6
USB3.0, IPMI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASMB-622 and is the answer not in the manual?

Questions and answers

Summary of Contents for Advantech ASMB-622

  • Page 1 User Manual ASMB-622 Dual LGA 4189 Intel® Xeon® Scalable Proprietary Server Board with 16 DDR4, 4 PCIe x16, 3 PCIe x8, 1 PCIe x4, 5 SATA3, 6 USB3.0, IPMI...
  • Page 2 No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
  • Page 3 Advantech has come to be known. Your satisfaction is our primary concern. Here is a guide to Advantech’s cus- tomer services.
  • Page 4 It should be free of marks and scratches and in perfect working order upon receipt. When unpacking the ASMB-622, check it for signs of shipping damage. (For example, damaged box, scratches, dents, etc.) If it is dam- aged or it fails to meet the specifications, notify our service department or local sales representative immediately.
  • Page 5: Table Of Contents

    2.16 Intel Virtual RAID (VROC1)..............25 Chapter AMI BIOS ..........27 Introduction ..................... 28 BIOS Setup ..................... 29 3.2.1 Main Menu .................. 29 3.2.2 Advanced BIOS Features Setup..........30 3.2.3 Platform Configuration ..............50 3.2.4 Socket Configuration..............59 ASMB-622 User Manual...
  • Page 6 SATA SGPIO Connector (SGPIO1)............97 Table B.11:SATA SGPIO Connector (SGPIO1) ......97 LPC Connector (LPC2) ................98 Table B.12:LPC Connector (LPC2) ..........98 B.10 Clear CMOS Connector (JCMOS1, JME1) ..........98 Table B.13:Clear CMOS Connector (JCMOS1, JME1) ....98 ASMB-622 User Manual...
  • Page 7: Chapter 1 Overview

    Chapter Overview...
  • Page 8: Introduction

    ASMB-622 the ideal platform for industrial server applications. By using the Intel C621A chipset, the ASMB-622 offers a variety of features such as 6 x USB3.0; 4 x onboard SATA III with Slim-SAS connector, 1 x SATA connector and 1 x M.2 2280 (SATA and PCIe) interface.
  • Page 9: Specifications

    2.50 mm) Power Connector Power Distribution Board on board, system power directly input from System/CPU Power power module (Input 12V, 5V, 3.3V, 5Vsb) PCIe slot power 2 x 4-pin 12V power connector for PCIe slot 12V input ASMB-622 User Manual...
  • Page 10 RoHS RoHS 6/6 Pb Free Compliant Operating Temperature: 0 to 40°C  Non-operating Temperature: -40 to 85°C  Environmental Spec. Operating Relative Humidity: 10% to 95% (non-condensing)  Non-operating Relative Humidity: 10% to 95% (non-condens-  ing) ASMB-622 User Manual...
  • Page 11: Board Layout, Jumpers And Connectors

    Board Layout, Jumpers and Connectors Connectors on the ASMB-622 are linked to external devices such as hard disk drives. In addition, ASMB-622 has a number of jumpers that are used to configure the system for specific applications. The tables below list the functions of each jumper and connector. Later sections in this chapter give instructions for setting jumpers.
  • Page 12 Blinking green Link Green Green 1000 Mbps Active Green Blinking green No Link Table 1.3: Jumpers Label Function Default JCMOS1 CMOS Clear JME1 ME update JWDT1 Watchdog Reset JCASE1 Chassis case open alarm JTHR_SEL On board(1-2)/external thermistor(2-3) ASMB-622 User Manual...
  • Page 13 Case open detection pin header JFP1 Front panel pin header JTHR_SEL1 Onboard thermister pin header LPC2 LPC port for debug & TPM module M2_2280_2 M.2 connector (SATA & PCIe x4) PCIE_STRA1 Connect to Flexible IO Board SATA_CON1 Serial ATA0~3 ASMB-622 User Manual...
  • Page 14 System is On On (Green): Off: 5VSB_LED1 Standby LED System is ON, in sleep No input AC Power mode, or in soft-off mode BMC heartbeat LED LED3 Blinking (Green): Controller is working normally (ASMB-622 T2 and I SKUs) ASMB-622 User Manual...
  • Page 15: Block Diagram

    1 x RS-232 conn. Figure 1.3 Block Diagram System Memory ASMB-622 has sixteen 288-pin memory slots for DDR4 2666/2933/3200 MHz mem- ory modules with maximum capacity of 1024 GB (Maximum 64 GB for each DIMM). ASMB-622 supports registered DIMMs memory module.
  • Page 16 Table 1.6: DIMM Configuration with single CPU Channel DIMMA1 DIMMB1 DIMMC1 DIMMD1 DIMME1 DIMMF1 DIMMG1 DIMMH1 Quantity memory installed ASMB-622 User Manual...
  • Page 17 1LM+AD MM 1/2 perf (2) DCPMM DRAM DCPMM DRAM DCPMM DRAM DCPMM DRAM AD: App Direct Mode; MM: Memory Mode; AD+MM: Mixed Mode.  DRAM: RDIMM, 3DS RDIMM, LRDIMM, 3DS LRDIMM  Any capacity of DCPMM is allowed  ASMB-622 User Manual...
  • Page 18: Processor Installation

    Processor Installation The 3rd Gen Xeon Scalable processor installation: Remove the dust cover. Install CPU on CPU carrier and align the pin 1 mark. ASMB-622 User Manual...
  • Page 19 Install the CPU clip assembly on the heatsink as a processor + heatsink module. Place the processor heatsink module into the motherboard bolster plate by using a T-30 screwdriver. ASMB-622 User Manual...
  • Page 20 ASMB-622 User Manual...
  • Page 21: Chapter 2 Connections

    Chapter Connections...
  • Page 22: Introduction

    The two USB 3.0 ports on the rear plate, two USB3.0 on-board type A and two USB3.0 on-board pin headers could reach transmission rates up to 5Gbps. Fuse pro- tection is supported and the USB interface can be disabled in the system BIOS setup. USB3_56 USB3_12 USB3_34 ASMB-622 User Manual...
  • Page 23: Lan Ports (Lan1~Lan5)

    LAN Ports (LAN1~LAN5) The ASMB-622 is equipped with four GbE LAN (LAN1~4) ports and one dedicated IPMI LAN (LAN5) port. They are all with RJ-45 jacks and supported by all major net- work operating systems. LAN1_2 LAN3_4 IPMI LAN5 LAN4...
  • Page 24: Serial Ports (Com1~2)

    Serial Ports (COM1~2) COM2 COM1 CPU Fan Connector (CPUFAN0~1) If a fan is used, this connector supports cooling fans that draw up to 1.5A (18W). CPUFAN0 CPUFAN1 ASMB-622 User Manual...
  • Page 25: System Fan Connector (Sysfan0~3)

    SYSFAN2_PWR SYSFAN1_PWR SYSFAN0_PWR SYSFAN1_PWM SYSFAN2_PWM Front Panel Connector (JFP1) Front Panel Connector is to connect will external switches and LEDs to monitor and control the ASMB-622. The front panel convert cable will pre-installed in HPC-6240 Chassis. JFP1 ASMB-622 User Manual...
  • Page 26: Power Led (Jfp1 Pins 14, 16)

    Front Panel LAN Indicator (JFP1 Pins 5~8, 17~20) JFP1 pins 5, 6, 7, 8, 17, 18, 19 and 20 connect to LAN indicator. 2.8.3 Reset Connector (JFP1 Pins 2, 4) Many computer cases offer the convenience of a reset button. ASMB-622 User Manual...
  • Page 27: Case Open (Jcase1)

    A chassis intrusion header is located at JCASE1 on the motherboard. Attach the appropriate cable from the chassis to be informed of a chassis intrusion when the chassis is opened. The default function is disabled and Pin 1-2 is bridged by a jumper cap. JCASE1 SATA SGPIO (SGPIO1) SGPIO1 ASMB-622 User Manual...
  • Page 28: Sata And M.2 Connector (Sata0~3, Ssata0 And M2_2280_2)

    SATA and M.2 Connector (SATA0~3, sSATA0 and M2_2280_2) ASMB-622 features five serial ATA III interfaces (up to 600 Gb/s) which SATA0~3 go with SFF-8643 on-board connector via cable to two 2 ports HDD backplane, total 4 ports. The M.2 2280 connector can support both SATA and PCIe SSD devices.
  • Page 29: Power Connector (Bp_P1, Bp_P2, Gpu_Cn1, Gpu_Cn2)

    GPU power cable for the GPU card external power requirement. Two HDD Backplane power connectors BP_P1 and BP_P2 provide enough power for the HDD Backplane. The on-board 4-pin power connects to one HDD Backplane power connector. GPU_CN1 GPU_CN2 BP_P1 BP_P2 ASMB-622 User Manual...
  • Page 30: Lpc Connector (Lpc2)

    2.13 LPC Connector (LPC2) ASMB-622 has one LPC connector that can be used for Advantech's TPM Module (P/N: PCA-TPM-00B1E) for security management. LPC2 2.14 CMOS Clear and ME Update Connector (JCMOS1, JME1) Set jumper from pin 1-2 to pin 2-3, then back to pin 1-2 to reset CMOS data.
  • Page 31: Hdd Backplane Smbus Connector (Smbus1)

    The Intel VROC license key of VMD allows NVMe SSDs to connect via PCIe and directly manage the CPU for better RAID performance. Enable NVMe SSD RAID, hot-plug and LED management features via the VROC connector. VROC1 ASMB-622 User Manual...
  • Page 32 ASMB-622 User Manual...
  • Page 33: Chapter 3 Ami Bios

    Chapter AMI BIOS...
  • Page 34: Introduction

    The Setup program uses a number of menus for making changes and turning the special features on or off. This chapter describes the basic navigation of the ASMB-622 setup screens. AMI's BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration.
  • Page 35: Bios Setup

    System Date using the <Arrow> keys. Enter new values through the keyboard. Press the <Tab> key or the <Arrow> keys to move between fields. The date must be entered in MM/DD/YY format. The time must be entered in HH:MM:SS format. ASMB-622 User Manual...
  • Page 36: Advanced Bios Features Setup

    3.2.2 Advanced BIOS Features Setup Select the Advanced tab from the ASMB-622 setup screen to enter the Advanced BIOS setup screen. You can select any of the items in the left frame of the screen, such as CPU configuration, to go to the sub menu for that item. You can display an Advanced BIOS Setup option by highlighting it using the <Arrow>...
  • Page 37 3.2.2.1 Trusted Computing Security Device Support  Enables or disables BIOS support for security device. Note! You need to purchase Advantech LPC TPM module to use TPM func- tion. P/N: PCA-TPM-00B1E. ASMB-622 User Manual...
  • Page 38 3.2.2.2 ACPI Settings Lock Legacy Resources  Enable or disable lock legacy resources feature. 3.2.2.3 IT8528 EC Super IO Configuration ASMB-622 User Manual...
  • Page 39 Serial Port 1 Configuration  – Serial Port Enable or disable serial Port 1. – Change Settings To select an optimal setting for serial port 1. ASMB-622 User Manual...
  • Page 40 Serial Port 2 Configuration  – Serial Port Enable or disable serial port 2. – Change Settings To select an optimal setting for serial port 2. ASMB-622 User Manual...
  • Page 41 The default of CPU/System FAN is Smart FAN mode and the BIOS will automat- ically control the FAN speed by CPU temperature. When set to manual mode, fan duty setting can be changed; the range is from 30%~100%, default setting is 50%. ASMB-622 User Manual...
  • Page 42 3.2.2.5 Serial Port Console Redirection ASMB-622 User Manual...
  • Page 43 Once the buffers are empty, a 'start' signal can be sent to re-start the flow. Hardware flow control uses two wires to send start/stop signals. Options available: None/Hardware RTS/CTS. – VT-UTF8 Combo Key Support Enable VT-UTF8 combination key support for ANSI/VT100 terminals. ASMB-622 User Manual...
  • Page 44 Resolution 100x31 Enables or disables extended terminal resolution. – Putty Keypad Select function key and keypad on putty. Legacy Console Redirection Settings  Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages. ASMB-622 User Manual...
  • Page 45 Above 4G Decoding  Enable or disable 64-bit capability. Devices to be decoded in above 4G address space (only if the system supports 64-bit PCI decoding). Note! Some graphic or GPU cards need to enable 4G Decoding. ASMB-622 User Manual...
  • Page 46 This is a workaround for OS without XHCI hand-off support. The XHCI ownership change should be claimed by XHCI driver. USB Mass Storage Driver Support  Enable or disable USB mass storage driver support. USB Transfer Time-out  Selects the USB transfer time-out value. [1,5,10,20sec] ASMB-622 User Manual...
  • Page 47 Device Reset Time-out  Selects the USB device reset time-out value. [10,20,30,40 sec] ASMB-622 User Manual...
  • Page 48 Device Power-up Delay  This item appears only when device power-up delay item is set to [manual]. Mass Storage Devices  Default is “Auto” to enumerate mass storage devices according to media format. ASMB-622 User Manual...
  • Page 49 3.2.2.8 Network Stack Configuration Enable or disable UEFI network stack function. ASMB-622 User Manual...
  • Page 50 3.2.2.9 CSM Configuration CSM Support  Enables or disable UEFI CSM (Compatibility Support Module) to support a leg- acy PC boot process. Default is Disabled. ASMB-622 User Manual...
  • Page 51  This item is useful when RT code is executed above 1MB. When it's set as “Upon Request”, GA20 can be disabled using BIOS services. When it's set as “Always”, it does not allow disabling of GA20. ASMB-622 User Manual...
  • Page 52 Option ROM Messages  To “Force BIOS or keep current” to set the display mode for Option ROM. Boot option filter  Change UEFI/legacy ROM priority for boot option. ASMB-622 User Manual...
  • Page 53 Network  Control the execution of UEFI and legacy PXE OpROM. Storage  Control the execution of UEFI and legacy storage OpROM. ASMB-622 User Manual...
  • Page 54 Video  Control the execution of UEFI and Legacy Video OpROM. Other PCI devices  Determines OpROM execution policy for devices other than Network., Storage, or Video. ASMB-622 User Manual...
  • Page 55 3.2.2.10 iSCSI Configuration Host iSCSI Configuration  The worldwide unique name of iSCSI Initiator. Only IQN format is accepted. Range is from 4 to 223. ASMB-622 User Manual...
  • Page 56: Platform Configuration

    3.2.3 Platform Configuration ASMB-622 User Manual...
  • Page 57 3.2.3.1 PCH Configuration PCH Devices  This item is to set up IO Controller Hub devices. Restore AC Power Loss  Specify what state to go to when power is re-applied after a power failure (G3 state). ASMB-622 User Manual...
  • Page 58 – VGA Priority Determines priority between onboard and 1st off-board video device found. Onboard VGA Controller  Enable/Disable Onboard VGA Controller (ASPEED AST2500). ASMB-622 User Manual...
  • Page 59 Detected Display Device From  Select to display from which PCIe Slot. RTC Wake system from S4/S5  Enable or disable system wake on alarm event. ASMB-622 User Manual...
  • Page 60 PCI Express Configuration  PCIE SLOT6  M2 PCIE SLOT Root Port Settings. ASMB-622 User Manual...
  • Page 61 PCIe Speed  Configures PCIe speed: options, Auto, GEn 1, Gen 2, Gen 3 PCH SATA Configuration  ASMB-622 User Manual...
  • Page 62 On an edge detect from 0 to 1, the PCH starts a COMRESET initialization sequence to the device. – SATA Port 0~3 Device Type To identify the SATA is connected to Solid State Drive or Hard Disk Drive. ASMB-622 User Manual...
  • Page 63 PCH sSATA (M.2) Configuration  – sSATA M.2 Controller Enable or disable SATA Controller. – sSATA M.2 Port Enable or disable SATA port. ASMB-622 User Manual...
  • Page 64 – LAN Controller Enable or disable Intel I350 Controller support. – LAN1~4 PXE OpROM Enable or disable Boot option for Intel I350 controller. ASMB-622 User Manual...
  • Page 65: Socket Configuration

    3.2.3.2 Server ME Configuration This page shows the Server ME configuration information. 3.2.4 Socket Configuration ASMB-622 User Manual...
  • Page 66 Processor Configuration Per-Socket Configuration  Use this to select how many processor cores you want to activate when you are using a dual or quad core processor. Hyper-threading [All]  Enable or disable Intel Hyper Threading technology. ASMB-622 User Manual...
  • Page 67 MLE and establish a mea- sured environment within the platform to support trust decisions by end users. AES-NI  This item is enable or disables CPU advanced encryption standard instructions. 3.2.4.2 Memory Configuration ASMB-622 User Manual...
  • Page 68 Display memory topology with DIMM population information. 3.2.4.3 IIO Configuration Socket0 PCIe Configuration  PCIe port bifurcation control and select target link speed as Gen1, Gen2, Gen3, Gen4 and Auto. Below is the BIOS setting reference to CPU0. ASMB-622 User Manual...
  • Page 69 ASMB-622 User Manual...
  • Page 70 ASMB-622 User Manual...
  • Page 71 ASMB-622 User Manual...
  • Page 72 Below is the BIOS setting reference to CPU1. ASMB-622 User Manual...
  • Page 73 ASMB-622 User Manual...
  • Page 74 Intel VT for Directed I/O (VT-d)  Enable or disable Intel Virtualization Technology for Directed I/O. ASMB-622 User Manual...
  • Page 75 Intel VMD technology  Enable or disable Intel Volume Management Device Technology. ASMB-622 User Manual...
  • Page 76 3.2.4.4 Advanced Power Management Configuration CPU P State Control  ASMB-622 User Manual...
  • Page 77 CPU C State Control  ASMB-622 User Manual...
  • Page 78: Server Management

    Package C State Control  3.2.5 Server Management BMC Support  Enable or disable interfaces to communicate with BMC. Wait for BMC  ASMB-622 User Manual...
  • Page 79 Choose options for erasing SEL. When SEL is Full  Choose options for reactions to a full SEL. Log EFI Status Codes  Disable the logging of EFI status codes or log only error code or only progress code or both. ASMB-622 User Manual...
  • Page 80 ASMB-622 User Manual...
  • Page 81 3.2.5.2 BMC Self Test Log Erase Log  Erase log options. When Log is Full  Select the action to be taken when the log is full. ASMB-622 User Manual...
  • Page 82 3.2.5.3 BMC Network Configuration Configuration Address Source  Select to configure LAN channel parameters statically or dynamically (by BMC). Unspecified options will not modify any BMC network parameters during BIOS phase. ASMB-622 User Manual...
  • Page 83 3.2.5.4 BMC User Settings ASMB-622 User Manual...
  • Page 84: Security

    3.2.6 Security ASMB-622 User Manual...
  • Page 85 Note! With AC power & battery. Short CMOS1 Jumper: Date/Time & Password: Keep Setting: reset to default AC power and CMOS battery are removed. Short CMOS1 Jumper: Date/Time: reset to default Password: Keep Setting: reset to default ASMB-622 User Manual...
  • Page 86 Secure Boot feature is active if Secure Boot is Enabled. Platform Key (PK) is enrolled and the System is in User mode. The mode change requires plat- form reset. – Secure Boot mode Secure Boot mode options. ASMB-622 User Manual...
  • Page 87 – Restore Factory Keys Force the system to user mode. – Key Management Enables expert users to modify Secure Boot Policy variables without full authentication. ASMB-622 User Manual...
  • Page 88: Boot

    Number of seconds to wait for setup activation key. Bootup NumLock State  Select the keyboard NumLock state as "On" or "Off". Quiet Boot  Enable or disable quiet boot option. Boot Option Priorities  Sets the system boot priorities. ASMB-622 User Manual...
  • Page 89: Save & Exit

    Restore/Load default values for all the setup options. Save as User Defaults  Save the changes done so far as user defaults. Restore User Defaults  Restore the user defaults to all the setup options. Boot Override  ASMB-622 User Manual...
  • Page 90 ASMB-622 User Manual...
  • Page 91: Driver Installation

    Chapter Driver Installation...
  • Page 92: Before Beginning

    Before Beginning To facilitate the installation of the enhanced display drivers and utility software, read the instructions in this chapter carefully. The drivers for the ASMB-622 are available online for download from the Advantech support website at: https://www.advantech.tw/search/?q=ASMB-622&st=support Before beginning, it is important to note that most display drivers need to have the relevant software application already installed on the system prior to installing the enhanced display drivers.
  • Page 93: Lan Configuration

    4.2.3 LAN Configuration The ASMB-622 has four Gigabit Ethernet LAN connections via dedicated PCI Express x4 lanes: GbE LAN1~4 via Intel I350 that offer bandwidth of up to 500 MB/ sec, eliminating the bottleneck of network data flow and incorporating Gigabit Ether- net at 1000 Mbps.
  • Page 94 ASMB-622 User Manual...
  • Page 95: Appendix A Programming The Watchdog Timer

    Appendix Programming the Watchdog Timer...
  • Page 96: Watchdog Timer Overview

    The ASMB-622’s watchdog timer can be used to monitor system software operation and take corrective action if the software fails to function within the programmed period. This section describes the operation of the watchdog timer and how to pro- gram it.
  • Page 97 0x29A, BIT1, = 0 Write 0x28 to 0x29A Start watchdog Wait 1 ~ 9 Wait IBF clear 0x29A, BIT1, = 0 Write 0x29 to 0x29A Stop watchdog Wait IBF clear 0x29A, BIT1, = 0 Go to Step 07 ASMB-622 User Manual...
  • Page 98 ASMB-622 User Manual...
  • Page 99: Appendix B I/O Pin Assignments

    Appendix I/O Pin Assignments...
  • Page 100: Usb3.0 Header (Usb3_34)

    Table B.1: USB Header (USB3_56) Signal Signal +5 V STDA_SSRX- STDA_SSRX+ STDA_SSRX-TX- STDA_SSRX+TX+ NC (reserved for OC pin) STDA_SSRX+TX+ STDA_SSRX-TX- STDA_SSRX+ STDA_SSRX- +5 V VGA Connector (VGA1) Table B.2: VGA Connector (VGA1) Signal Signal GREEN BLUE H-SYNC V-SYNC ASMB-622 User Manual...
  • Page 101: Interface (Com2)

    System & CPU Fan Power Connector (SYSFAN0~3, CPUFAN0~1) Table B.4: CPU FAN Connector (CPUFAN0~CPUFAN1) CPUFAN0 CPUFAN1 +12V +12V CPU_FAN0_TACH CPU_FAN1_TACH CPU0_PWM CPU1_PWM Table B.5: SYS FAN PWR Connector (SYSFAN0_PWR~SYSFAN2_PWR) SYSFAN0_PWR SYSFAN1_PWR SYSFAN2_PWR +12V +12V +12V FAN_PSNT0 FAN_PSNT1 FAN_PSNT2 ASMB-622 User Manual...
  • Page 102: Fan2_Pwm)

    SYSFAN0_PWM SYSFAN1_PWM SYSFAN2_PWM GND1 GND1 +12V +12V +12V SYSFAN0_TACH SYSFAN1_TACH SYSFAN1_TACH SYS_FAN_ZONE1_PWM SYS_FAN_ZONE1_PWM SYS_FAN_ZONE2_PWM Table B.7: SYS FAN3 Connector (SYSFAN3) SYSFAN3 SYS_FAN_ZONE3_PWM +12V FAN_PSNT3 SMBus Connector (SMBUS1) Table B.8: Front panel SMBus Connector (SMBUS1) Signal SMB_SCL_FRU SMB_SDA_FRU ASMB-622 User Manual...
  • Page 103: Lan Ports (Lan1~Lan4, Ipmi Lan5)

    Signal Signal MID0+ MID2+ MID0- MID2- MID1+ MID3+ MID1- MID3- Case Open Connector (JCASE1) Table B.10: Case Open Connector (JFP1) Signal CASEOP SATA SGPIO Connector (SGPIO1) Table B.11: SATA SGPIO Connector (SGPIO1) Signal SCLOCK_PCH SLOAD_PCH SDATAOUT0_PCH SDATAOUT1_PCH ASMB-622 User Manual...
  • Page 104: Lpc Connector (Lpc2)

    Table B.12: LPC Connector (LPC2) Signal Signal CLK_24M_LPCCN LPC_AD1 PLTRST_LPC LPC_AD0 LPC_FRAME +3.3V LPC_AD3 LPC_AD2 SMB_SCL_LPC SERIRQ_PCH SMB_SDA_LPC +5V_AUX B.10 Clear CMOS Connector (JCMOS1, JME1) Table B.13: Clear CMOS Connector (JCMOS1, JME1) JCMOS1 JME1 Signal Signal RTC_RST_PCH HDA_SDOUT_PCH +3.3V_AUX ASMB-622 User Manual...
  • Page 105 ASMB-622 User Manual...
  • Page 106 No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2022...