Cartridge Assembly - jbc ALE-908VA Manual

Automatic-feed soldering station
Table of Contents

Advertisement

C
º
Sel. temp. 325ºC
Upda�ng
1.00mm
Step 2
Your sta�ons is being updated
Reel Locking Assembly
Con�nuous
24.0
mm/s
75%
Supplied: 12 mm
To assemble the reel locking, its conical side must be pointing downwards (1).
Ø 1.00 mm
Reel Locking
Yes
No
USE ONLY WITH A 250 V FUSE
Align the flat side of the axis (2) with the inner flat side of the reel locking (3).
EARTH FUSE F1.25 A
Make sure that the reel locking screw is slightly backed out and does not collide with the axis.
Reassemble the reel locking to the axis (4).
Note: To prevent the solder reel from spinning freely or binding, gently press the reel locking down, but only enough to allow the solder reel to
rotate freely, before tightening the reel locking screw (5).
4

Cartridge Assembly

Step 3
For a safe cartridge assembly/change, make sure that the tool is
unplugged and the cartridge has cooled down.
Loosen the cartridge set screw (1) and insert the cartidge up to its
mark
(2). Important: It is essential to insert the cartridge completely
for a good connection.
Adjust the tip direction (3) and tighten the cartridge set screw (1).
Flat Side of the
Reel Locking
3
Reel Locking
5
Screw
Flat Side
of the Axis
2
Reel Locking
EARTH FUSE F1.25 A
Reel Locking
Top View
AL250
Cartridge Set Screw
1
Conical
Side
Flat Side
(Reel Locking)
3
1
Mark
3
2
5

Advertisement

Table of Contents
loading