SCT-1SX-MODBUS TCP/IP
Quick Start Guide
September 29, 2023
PN 219717 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCT-1SX-MODBUS TCP/IP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rice Lake SCT-1SX-MODBUS TCP/IP

  • Page 1 SCT-1SX-MODBUS TCP/IP Quick Start Guide September 29, 2023 PN 219717 Rev A...
  • Page 3: Electrical Schematic

    12 to 24 Vdc LPS or Class 2 power source. 12 13 14 15 16 17 LOAD CELL Internal use Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals Warranty information is available at www.ricelake.com/warranties © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 4: Key Functions

    SCT-1SX-MODBUS TCP/IP 2. Key Functions      Configuration menu Weighing mode Decreases digit / Scrolls down. Clears the displayed gross weight. Increases digit / Scrolls up. Short press: executes semiautomatic tare. Long press: allows to enter known tare.
  • Page 5: Configuration Menu

    Date and time setting (with optional card only). HOW TO EXIT THE MENU AND SAVE YOUR CONFIGURATION 1. Press key repeatedly until save? appears; press to save or press to exit without saving. © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 6: Theoretical Calibration

    SCT-1SX-MODBUS TCP/IP 5. Maximum Scale Capacity, Increment and Decimal Point Settings Set the decimal point position and the minimum scale increment* div.deC 888888 0,001 0,002 0,005 0,01 0,02 0,05 div.deC CapaC Set the maximum scale capacity* 999999 (max Examples: For a 60000 lb scale, with 2 lb For a 10000 g scale, with 0.1 g increment:...
  • Page 7 It allows to verify signal of each channel. It must be included into the range 0 to 3 mV/V. adC.v Signal have to be stable and it have to increase by increasing the weight on the scale. © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 8: Input Settings

    SCT-1SX-MODBUS TCP/IP 10. Input Settings 888888 div.deC inps div.deC inp.01 INP.02 inp.02 none Input disabled. dis.key When input is active, transmitter keyboard is locked. When input is active, transmitter reboots. Emulation of key. prin Emulation of key. mode Emulation of key.
  • Page 9: Output Settings

    12. Fieldbus Settings 888888 div.deC FLDBUS div.deC Fb.ini mod.Cp Fb.Se? Set the IP address: Fb.Se div.deC a.CfG Dynamic IP address. ip.add Static IP address. ne.msk Subnet mask. Ga.way Default gateway. © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 10: Programming Errors

    SCT-1SX-MODBUS TCP/IP 13. Weight Filter 888888 div.deC filer The active weight filter is displayed, alternating with the weight value. Press keys to scroll through the available filters (from slowest to fastest, F1 to F11). 14. Programming Errors MESSAGE DESCRIPTION SOLUTION First calibrate the zero point (zero), then proceed with sample preC.
  • Page 11: Modbus Tcp

    Digital output 2 status (0 = OFF; 1 = ON). Bit 0 Digital output 1 status (0 = OFF; 1 = ON). (lsb) Selected page 30008 Shows the value of the selected page (3001). µV 30009 µV value. © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 12 SCT-1SX-MODBUS TCP/IP 15.2 MODBUS TCP REGISTERS FOR COMMAND SENDING Data Register DESCRIPTION Main available commands: Value Command 00 Hex No command 01 Hex Scale zeroing 02 Hex Tare Command 40001 03 Hex Preset Tare 0A Hex Setpoint 1 setting 0B Hex...
  • Page 13 Modbus TCP Notes © Rice Lake Weighing Systems • All Rights Reserved...
  • Page 14 SCT-1SX-MODBUS TCP/IP Notes Visit our website www.RiceLake.com...
  • Page 16 © Rice Lake Weighing Systems Content subject to change without notice. 230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171 September 29, 2023 PN 219717 Rev A www.ricelake.com...