WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating
air passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected yearly by a qualified service techni-
cian. Heater may need more frequent cleaning due to excessive lint
from carpeting, bedding material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the
burner(s) clean may result in sooting and property damage.
CAUTION: Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/ pilot unit.
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.
The primary air inlet hole allows the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep this hole
clear of dust, dirt and lint. Clean this air inlet
hole prior to each heating season. A blocked
air hole will create soot. We recommend that
you clean the unit every three months during
operation and have heater inspected yearly
by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSl.
Your local computer store, hardware store,
or home center may carry compressed air in
a can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner and pilot for dust and dirt.
Use pressurized air to clean.
Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
18

CARE AND MAINTENANCE

ODS/PILOT AND BURNER
BURNER PILOT AIR INLET
CABINET
Air Passageways
Exterior
www.usaprocom.com
3. Blow air across the ports/slots and holes
in the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
about 2" from where the pilot flame comes out
of the pilot assembly (see Figure 24). With
the unit off, lightly blow air through the air
inlet. You may blow through a drinking straw
if compressed air is not available.
Thermocouple
Ignitor Electrode
Figure 24 - Pilot Inlet Air Hole
Pilot Assembly
Pilot Air Inlet Hole