Installing the heating water buffer cylinder
Installation information
Danger
Intense heat from a naked flame will melt the
thermal insulation. The resulting vapours may
be harmful to health.
Prevent the thermal insulation from coming into
contact with naked flames, e.g. when welding
and brazing.
!
Please note
To prevent material losses, install the heating
water buffer cylinder in a room free from the risk
of frost and draughts.
When not in use, the heating water buffer cylin-
der must be drained if there is a risk of frost.
Installing the heating water buffer cylinder with immersion heater EHE
Minimum clearances
a
Fig. 1
8
Provide adequate clearance from the wall to allow for
operation of the temperature controller (if installed).
Placing the heating water buffer cylinder on a plinth
will make the room easier to clean.
Use the adjustable feet to level the heating water
buffer cylinder.
Immersion heater EHE installation instructions
Maintain minimum clearances.
Note
The unheated length of an immersion heater EHE
installed on site must be at least 100 mm.
Max. output
Dimension a
6 kW
12 kW
Dimension b
550 mm
650 mm
750 mm
650 mm