Installing connections on the solar side
8.
6.
4.
3.
Fig. 22
3. Push the corrugated hose into the elbow.
4. Screw the air vent plug into the elbow.
5. Push the corrugated hose into the solar flow and
secure the elbow with flat gasket to the cylinder.
6. Fit the solar flow pipe.
Heating water buffer cylinder with Vitotrans and with Solar-Divicon
(cont.)
5.
7.
7. Fit the solar return pipe.
8. Before the Divicon is fitted: Attach thermal insula-
tion to the pipes – the long section to the left-hand
pipe, the short section to the right-hand one.
27