6-11 Maintenance to be carried out by a fitter or qualified technician
The following maintenance operations must be carried out at least once a year:
- Check the efficiency of the thermostatic solenoid valve and of the safety thermostat;
- Check the pressure and sealing of the system;
- Check safety thermocouple efficiency;
- Check the efficiency of the fume extraction system (if any);
- Check safety thermostat efficiency;
- Check combustion;
- Check the minimum adjustment screw to ensure it is sealed; sealing must be intact.
DANGER
Before carrying out any repair or maintenance operation on the appliance, turn off the gas supply
tap .
6 .11 .1 Burner cleaning
Clean the burners as follows:
- Unscrew the burner fixing screws and remove it from its seat;
- Clean the gas outlet holes by means of a drill (for instance, a twist drill) or a similar tool;
- Once cleaned, refit the pieces in reverse order;
- Check the combustion gas extraction duct and the anti-draught device (if present).
© Copyright 2015
Instructions for qualified fitters
GAS PASTA COOKER - LADY 900
6
49