Download Print this page

Advertisement

Quick Links

Installation instructions
Induction hon
GK46TIMPS | GK47TIMPS
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in
the order specified.
Validity
These installation instructions are valid for the following models:
Product family
31079
31080
General notes
The directives and standards for low-voltage installations and fire protection must be complied with when installing
in flammable material.
Identification plate
The identification plate is located next to the connec-
tion plate.
Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appli-
ance.
Installation accessories supplied
Flush installation:
Designation
Cementing-in instructions
Sealing tape set
Spacer set
Accessories
For all installation variants:
Designation
Ventilation protective plate set for niche width 825 mm
Ventilation protective plate set for niche width 900 mm
Flush installation:
Designation
Steel angle set, installation dimension 90
Instant adhesive for installing the steel angle
Permabond F246 incl. activator, 50 ml tube. From Silitech AG, 3008 Bern.
Sealant set
Complete with cleaning agent, primer type 1105, cartridge with black silicone adhesive, with nozzle.
Suitable for all absorbent covering materials (wood and types of natural stone such as marble and
granite).
Special primer type 107
Suitable for non-absorbent covering materials (not suitable for polyethylene, polypropylene or Teflon).
With dual design
GK47TIMPSZ
GK46TIMPSZ
Connection plate
1
Identification plate
1021075-R01
29/11/2016
Art. No.
J004133
H63283
H60330
Art. No.
H61088
H61089
Art. No.
H63775
B11502
86.3928.85
45.2771.76

Advertisement

loading

Summary of Contents for V-ZUG GK46TIMPS

  • Page 1 1021075-R01 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order specified. Validity These installation instructions are valid for the following models:...
  • Page 2 1021075-R01 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS Electrical connection Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards for low-voltage installations and the specifications of the local electricity supply companies. A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications.
  • Page 3 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS General information about installation ▪ The worktop must be flat so that it is sufficiently sealed against the ingress of liquids. ▪ In order to guarantee good ventilation, a space of at least 10 mm in height is necessary beneath the appliance.
  • Page 4 1021075-R01 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS Flush installation The cooking ring layout of the hob to be fitted can differ from the hob illustrated. GK46TIMPSZ, GK47TIMPSZ Cable length 1.7 m W – W Y – Y Drawer/cabinet...
  • Page 5: Flush Installation

    1021075-R01 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS Cool air supply with regard to drawer or cabinet installed below To ensure good ventilation, there must be ≥ 10 mm of space under the appliance. Framed installation (263) ≥360 (43) ≥240 C ≥200...
  • Page 6 Installation instructions 29/11/2016 Induction hon GK46TIMPS | GK47TIMPS Installation of the ventilation protective plate with 3 mm ventilation gap at the front A ventilation protective plate is required to ensure sufficient ventilation of the hob. There must be a distance of ≥ 10 mm between the underside of the appliance and the ventilation protective plate.

This manual is also suitable for:

Gk47timpsGk47timpszGk46timpsz3107931080