6.1 RS232 port
Default baud rate of RS-232C ports: 115200bps.
6.2 RS485 port and CAN port.
Default baud rate of RS-485 port: 9600bps
Default baud rate of CAN port: 500K
Table 6-2 RS485 and CAN Connector Pin Assignments
Pin number
1
2
3
4
5
6
7
8
7 Troubleshooting
Please refer to the troubleshooting methods mentioned below. Please read the "Table 7-1 LED indica-
tion" of this manual before troubleshooting to avoid false operations.
For example, the blinking or constant red light of the ALM alarm on the front panel does not necessarily
indicate a faulty battery. In most cases, the "alarm" indication signifies normal operation and requires no
troubleshooting. Furthermore, if the battery indicates "protection," it will resume normal operation
automatically once the "protection" status is released.
Protection /
Battery
Alarm /
status
Normal
Shut down
Power-on
Normal
Normal
Standby
Alarm
Normal
Alarm
Charging
Protection
Normal
Alarm
Discharge
Protection
Note: The blinking descriptions: Blink 1"0.3s on/3.7s off"; Blink 2 "0.5s on /0.5s off";Blink 3"0.5s on / 1.5s off";
Blink 4"0.7s on / 9.3s off"
Serial
RS485B
RS485A
GND
GND
RS485A
RS485B
ALM
RUN
●
●
OFF
OFF
ON
ON
OFF
Blink 1
Blink 3
OFF
OFF
Light
Blink 3
Light
Light
OFF
OFF
Blink 3
Blink 3 Blink 3
Light
OFF
Table 6-1 RS232 Connector Pin Assignments
CAN
CANH
CANL
Capacity LED
OFF
ON
OFF
OFF
Base on capacity
OFF
Base on capacity
OFF
15
Pin number RS-232C port
1
2
3
RXD
4
GND
5
6
TXD
7
8
Table 7-1 LED indications
Descriptions
All off
All lights stay on simultaneously
for one second
standby
Low voltage
Protection triggered,
charging stops
Protection triggered,
discharging stops
Need help?
Do you have a question about the V Series and is the answer not in the manual?
Questions and answers