Register Description - Ebyte E95-DTU 433C 485-V2 Series Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
2
Read registers
Setting Temporary
3
Registers
Wireless
Configuration
(remote target
5
device must be in
general mode)
6
format error

5.2 Register description

seri
Read/W
al
rite
Name
numb
er
Read/
00H
ADDH
Write
Read/
01H
ADDL
Write
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
Command: C1 + start address + length
Response: C1 + start address + length + parameters
Example 1: Read channel
Command Start address Length Parameters
Send: C1 05 01
Return: C1 05 01 09
Example 2: Read radio address, network address, serial port, airspeed at the
same time
Send: C1 00 04
Return: C1 00 04 12 34 00 61
Command: C2 + start address + length + parameters
Response: C1 + start address + length + parameters
Example 1: Configure the channel as 0x09
Command Start address Length Parameters
Send: C2 05 01 09
Return: C1 05 01 09
Example 2: Configure radio address (0x1234), network address (0x00), serial
port (9600 8N1), airspeed (1.2K) simultaneously
Send: C2 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
Command: CF CF + regular command
Response: CF CF + regular response
Example 1: Wireless configuration channel is 0x09
Wireless Command Header Command Start Address Length Parameters
Send: CF CF C0 05 01 09
Return: CF CF C1 05 01 09
Example 2: Wireless configure radio address (0x1234), network address (0x00),
serial port (9600), airspeed (1.5K) at the same time.
Send: CF CF C0 00 04 12 34 00 61
Return: CF CF C1 00 04 12 34 00 61
Format Error Response
FF FF FF FF
Description
ADDH (default 0)
ADDL (default 0)
E95-DTU(433Cxx-485)-V2.0 User manual
Remark
* High and low byte of the radio
station address;
* Note: When the radio station
address is equal to FFFF, it
can be used as a broadcast and
listening address, i.e.: the
radio station will not be
address
filtered
at
point.
this
16

Advertisement

Table of Contents
loading

Table of Contents