2. If BMC communication is unavailable, use F1 Setup to access System Event Logs Menu and Choose
Clear BMC System Event Logs and Restart Server.
• FQXSFSM0008M: Boot permission timeout detected.
Severity: Error
User Action:
Complete the following steps:
1. Review XCC logs for communication errors and resolve.
2. AC cycle the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFSR0001M: [arg1] GPT corruption detected, DiskGUID: [arg2]
Severity: Warning
Parameters:
[arg1] GPT corruption location. "Primary"Only primary GPT partition table corruption. "Backup"Only
backup GPT partition table corruption. "Both Primary and Backup"Both GPT partition tables corruption.
[arg2] Disk GUID.
User Action:
Complete the following steps:
1. Remove all the external drive during POST to avoid that this event is triggered by mistake.
2. Check the XCC event log. If this event has a follow up recovery event log, it means that GTP
corruption has been recovered successfully. Ignore this event message and do not perform the
remaining steps.
3. Back up the data disk.
4. Press F1 Setup->System Settings->Recovery and RAS->Disk GPT Recovery and set the value to
"Automatic".
5. Save the settings and restart the system.
6. Boot to F1 setup. The system will automatically try to recover the GPT during the POST.
7. Restart the system.
8. Re-format the LUN or disk and re-install the OS.
9. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFSR0002I: [arg1] GPT corruption recovered, DiskGUID: [arg2]
Severity: Info
Parameters:
[arg1] GPT corruption location. "Primary"Only primary GPT partition table corruption. "Backup"Only
backup GPT partition table corruption. "Both Primary and Backup"Both GPT partition tables corruption.
[arg2] Disk GUID
User Action:
Information only; no action is required.
• FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
.
191
Chapter 3
UEFI events