This message is for the use case where a user has successfully flashed the firmware component (MC Main
Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure
Power Backplane, Integrated System Management).
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0035
User Action:
Information only; no action is required
• FQXSPUP4002I: Flash of [arg1] from [arg2] failed for user [arg3].
This message is for the use case where a user has not flashed the firmware component from the interface
and IP address due to a failure.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0036
User Action:
Information only; no action is required
• FQXSPUP4003I: [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the
[arg3] firmware.
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0042
User Action:
Reflash the XCC firmware to the latest version.
• FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt
to flash the XCC firmware to the same level on all nodes/servers.
A mismatch of XCC firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0132
User Action:
Attempt to flash the XCC firmware to the same level on all nodes.
.