Table of Contents

Advertisement

DISASSEMBL Y OF KODAK CHEVRON CAMERA
1.
Remove the shutter trigger release screw and lift the
release out of the socket.
2. Set the focus ring to the Inf. position. Hold the shutter
securely to prevent bending the tube guides and then re-
move the shutter retaining collar using tool No.
850.
3. Set the finder mask (arrow 1) to the
828
position. Re-
move the exposure counter dial screw
(arrow
2) and lift
out the dial.
To assist in reassembly note the location
and number of washers under the dial.
.4
4. Remove the left and right t0f> housing screws located
in the spool chambers and lift off the housing.
5. Lift the IUJ{s of the rear eyelet frame and remove the
frame (arrow
I),
eye piece mask (arrow 2), lens tension
mask, eyelet fens, and deviator lens (not shown).
6. Remove the parallax frame screws using tool No. 30
and No.
887.
Lift oHthe parallax frame assembly.