4Q. Replace the metering pawl (arrow 1), spring (arrow
2), and the retainer ring (arrow 3).
41. Replace the range finder adjusting mask assembly
(arrow 1) (see paragraph 56, "Adjusting Po inter in Upper
Field" and "Masking of Upper Field"). Then replace the
movable mirror pivot stud (arrow 2) using a
3/
8" hexag-
onal nut driver.
42. Replace the stationary mirror bracket assembly (see
paragraph 56, "Adjusting Footage" 2{ b) and "Adjusting
Halving")
.
SERVICE MANUAL
NO.
5510-A
43. Lubricate the pivot points (arrows) of the movable
mirror bracket with No. 7101 grease, or equivalent.
Re-
place the bracket (see Instruction No. 45 for proper posi-
tioning of arm on cam (arrow).
44. Replace the movable mirror bracket spring.
45. Replace the movable mirror and clip.