46. Replacethe movable mirror adjustingscrew(see para
-
graph 56, "Ad justing Footage 1 and 2 (a)
).
47. Replace the parallax frame assembly
.
Increase the
tension of the assembly, if
necessary,
by reforming it at
the point indicated by arrow
1.
Too much tension will
cause horizontal movement of the frame
.
48.
R~place
the finder eyelet lens (arrow 1), plano side
to rear, the deviator lens with right angle side to rear
(arrow 2), lens tension mask (arrow 3)
.
12
49
.
Replace the eye piece mas
k
(arrow
2),
and the eyelet
fr9 me (arrow 1).
50. Set the finder mask to the 828 position
.
Then replace
the top housing and the top housing screws (short screw
on right side)
.
51. Replace the counter dial washers (thick washer f irst);
place the counter dial in position and secure it with the
dial screw
.